Assembly Instructions
14X30X12 Round Utility
V2.3
Please Do NOT Return Assembly to Dealer or Store. For All Assemb
oducts directly
Customer Service 800-447-70
8
ly Questions or Shortages Please Call MDM Pr
79 or 203-877-7070
Assembly with the Main Cover colored side showing
from the outside of the unit.
Step 2.
Loosen the 4 ratchets. Place the hook that is
attached to the ratchet strap into the outer hole in the
foot of each end arch.
Step 3.
It is important that your cover is laying square
over the frame before you start ratcheting down the
cover. Once the cover is even on all four sides, slowly
start ratcheting down all four corners.
Warning: Do not over tighten the ratchet straps.
Pay close attention to how tight the cover is put onto the
frame. It should be tight enough so it does not flap
around in the wind, but not so tight that it tears the
material cover. The fabric backed PE fabric of Rhino
Shelter units does not stretch. If you pull it so tight that
the fabric is stretched, a small amount of additional
stress from wind or contact can cause premature tears
and material failure. Only tighten cover enough to
remove valleys between arch assemblies. Do Not over
tighten.
Once the ratchet starts becoming harder to tighten
stop so you do not damage the cover.
Step 4
. When the cover is completely aligned secure
the cover to the bottom tie-down cross rail using the rope
provided. Start at one end and tie off the rope to the
cross rail. Lace the rope through the grommets in the
cover and back under the tie-down cross rail. Repeat
this on the opposite side.
A Roll Up Door Kit is supplied as standard for one end
door on the Utility Building. Refer to the instructions for
proper assembly. This assembly will make it easy to
open and close the tall door for entry and exit.