All of your individual wireless detectors (i.e. Wireless PIR, Wireless Reed, or Wireless Smoke Detectors) can send a 
supervision report to your receiver to confirm that they are fully functional.  
 
If supervision mode is enabled, the receiver will be expecting to receive the individual supervision code from each detector 
approximately every 2.4 hours i.e. at least 10 reports per day, per detector.  
 
The KISS-RX only requires one report from each detector during the 24 hour period to satisfy the supervision criteria. An 
extra 9 reports are still given to ensure that the supervision report is received.  
 
If all 10 supervision reports are missed from one detector during the 24 hour time frame, then the supervision output will be 
activated (it will switch low for 2 seconds). 
 

TURNING SUPERVISION ON OR OFF  (Default setting is 
OFF)

 

 

To turn on supervision: 

 
1.  Disconnect power from the receiver.  
 
2.  On Bank 1, set dip switches 1 & 8 to ON.  
 
 
 
 
 
3.  Reconnect power. The yellow program LED will begin to flash at 0.5Hz. 
      Within 60 seconds, press the Add Button. The green run light will turn on. 
 
 
 
 
4.  Supervision Reporting has now been activated for all zones. 
 
5.  Return all dip switches back to the OFF position. The yellow program LED will turn off. 

 

To turn off supervision: 

 

1.  Disconnect power from the receiver. 
  
2.  On Bank 1, set dip switches 1 & 8 to ON.  
 
 
 
 
 
3.  Reconnect power. The yellow program LED will begin to flash at 0.5Hz.  
      Within 60 seconds, press the Delete Button. The green run LED will turn off. 
 
 

1     2     3     4     5     6     7     8  

Bank 1 

ON 

 

OFF 

1     2     3     4     5     6     7     8  

Bank 1 

ON 

 

OFF 

%

 

Add 

%

 

Delete 

1     2     3     4     5     6     7     8  

Bank 1 

ON 

 

OFF 

 

Bank 1 

ON 

 

OFF 

Summary of Contents for KISS-RX

Page 1: ...hnology remotes can not be copied by scanning or code grabbing Remote Functions include Arm Disarm Panic Ability to quickly add or erase detectors from your system 4 Wireless Detector Zones Available...

Page 2: ...As soon as you release the alarm will respond PANIC Activate by pressing holding down the button for 3 seconds This sets off the siren To cancel panic press the button once Red Red Yellow Green Receiv...

Page 3: ...3 All outputs are open collector This means the outputs will be open circuit normally and will output ground earth for 1 second when triggered...

Page 4: ...M zone Address 01 Data 11000 First digit indicates number of keypads for Penta software version 4A123 SPECIAL NOTE This setup is designed for use with the PENTA control panel When using this module yo...

Page 5: ...ault your receiver follow these steps 1 Set all dipswitches on Bank 1 to ON 2 Press Hold the delete button for 1 second 3 All LED s on the receiver will flash once together to confirm that the receive...

Page 6: ...come on If the LED flashes check that you don t have more than one dipswitch set to on 2 Press the Delete Button 3 All remote controls will now have been erased from the memory of the receiver Due to...

Page 7: ...7 4 Return dip switch 8 to the OFF position The yellow Program light will turn off IMPORTANT NOTE When installing any wireless device make sure that it is at least 5 METRES AWAY from the receiver...

Page 8: ...code from the other zone 2 Press the Add Button The red Valid LED will start flashing at 0 5Hz 3 Now trigger the sensor The valid light will stop flashing once the detector has been successfully progr...

Page 9: ...iggering the detector and watching that the Valid LED no longer illuminates on your receiver when the detector transmits and also by watching that the Zone LED no longer illuminates on your RHINO Keyp...

Page 10: ...e then the supervision output will be activated it will switch low for 2 seconds TURNING SUPERVISION ON OR OFF Default setting is OFF To turn on supervision 1 Disconnect power from the receiver 2 On B...

Page 11: ...ies a different low battery code for each individual detector When you replace the batteries your receiver will automatically see that the low battery code is no longer being sent from that detector T...

Page 12: ...hat are sending the respective signal to your receiver will be illuminated on your alarm panel keypad for only 20 seconds The memory is then automatically erased so make sure you make careful note of...

Reviews: