background image

| 18 |

EN

Installation

1.  Shut off the electrical power supply where the product is to be installed
2.  Fix the 

R

ialto

 S

maRt

 m

eteR

 to the wall or other mounting surface and 

make the connections as in the diagram (fig. 1)

3.  Restore electrical power
4.  Check that the indicator Led is alight (red and blinking)
5.  Start the 

“R

ialto

” a

pp

, select “Add device” to initiate the procedure that 

will add the 

S

maRt

 m

eteR

 to the Rialto network

6.  Follow the guided procedure provided by the App for adding a 

S

maRt

 

m

eteR

 to the 

R

ialto

 network

L

L

N

N

Load

fig. 1

Summary of Contents for Smart Meter ZR-HM.W-RI

Page 1: ...Smart Meter Installation manual ...

Page 2: ......

Page 3: ... Installazione 10 Specifiche tecniche 12 Conformità 13 Sicurezza e smaltimento 13 Informazioni ed assistenza 13 EN Installation manual 14 General description 14 Safety warnings 15 Rialto Smart Meter 16 Installation 18 Technical specifications 20 Conformity 21 Safety and disposal 21 Information and support 21 ...

Page 4: ...cations techniques 28 Conformité 29 Sécurité et élimination 29 Informations et assistance 29 DE Installations und Bedienungsanleitung 30 Allgemeine Beschreibung 30 Sicherheitshinweise 31 Installation 34 Technische Daten 36 Konformität 37 Sicherheit und Entsorgung 37 Informationen und Support 37 Note Notes Notes Anmerkungen 38 ...

Page 5: ... Codice Code Nome Name ZR HM W RI Rialto Smart Meter IT Leggere e conservare queste istruzioni EN Read and keep these instructions FR Lisez et conservez ce manuel DE Diese Anleitung lesen und aufbewahren ...

Page 6: ... di dispositivi elettrici con elevati consumi Ha inoltre funzione di ripetitore del segnale wireless per gli altri dispositivi Rialto installati Requisiti minimi Per utilizzare Rialto Smart Meter sono necessari Una Whitebox Rialto precedentemente installata presente in tutti i Rialto Kit Dispositivo mobile smartphone tablet con sistema operativo Android o Apple iOS Contenuto della confezione 1 Ria...

Page 7: ...ti per il raggiungimento dei risultati previsti dal singolo prodotto La responsabilità di Astrel Group in relazione ai propri prodotti è regolata dalle Condizioni generali di vendita Astrel Group consultabili sul sito www astrelgroup com Attenzione Rialto Smart Meter deve essere utilizzato in ambienti interni ed asciutti evitan do il posizionamento in luoghi soggetti ad elevata umidità e o spruzzi...

Page 8: ... 8 IT Rialto Smart Meter 1 3 2 4 1 LED di segnalazione 2 Pulsante 3 Trasformatore amperometrico TA 4 Cavo di alimentazione ...

Page 9: ...ete Rialto NOTA il LED non fornisce indicazioni sullo stato di comunicazione wire less con la centralina WhiteBox la qualità del segnale è visibile sulla App Rialto Funzione pulsante tab 2 Funzione Comando Significato Prima configurazione Pressione breve circa 1 sec Aggiunta di Smart Meter alla rete wireless Rialto Reset Pressione prolungata circa 20 sec Ripristino impostazioni di fabbrica ...

Page 10: ...ma fig 1 3 Ripristinare l alimentazione dell impianto 4 Verificare che il LED di segnalazione sia acceso rosso lampeggiante 5 Avviare la App Rialto selezionare Aggiungi un dispositivo per ini ziare la procedura di aggiunta di Smart Meter alla propria rete Rialto 6 Seguire la procedura guidata descritta dalla App per aggiungere uno Smart Meter alla propria rete Rialto L L N N Load fig 1 ...

Page 11: ...o dispositivo aggiunto 9 Verificare che alimentando il carico elettrodomestico che si intende monitorare il dispositivo Smart Meter riporti il valore di potenza consu mata all interno dell App ATTENZIONE in caso di copertura insufficiente del segnale wireless tra Rialto Smart Meter e centralina WhiteBox visitare il sito www rialtocomfort com o contattare il Servizio Assistenza ...

Page 12: ...dalità di lettura TA apribile incluso Misure Potenza attiva W energia attiva kWh Potenza max misurabile 15 kW Parametri ambientali Condizioni di utilizzo 0 50 C 80 U R n c Condizioni di stoccaggio 20 70 C 80 U R n c Grado di protezione IP30 Isolamento Classe I Grado di inquinamento PD2 Categoria sovratensione II Conformità ETSI EN 300 328 ETSI EN 301 489 1 ETSI EN 301 489 17 EN 60730 1 EN60730 2 1...

Page 13: ...odotto è conforme ai requisiti essenziali ed alle disposizioni pertinenti stabilite dalla direttiva 2014 53 UE RED La dichiarazione di conformità può essere consultata sul sito www astrelgroup com Sicurezza e smaltimento Apparecchiatura elettrica ed elettronica oggetto di raccolta separa ta in conformità alle vigenti normative locali in materia di smalti mento Informazioni ed assistenza Per maggio...

Page 14: ...l devices with high power demands It also functions as a wireless signal repeater for other Rialto devices installed Minimum requirements To use the Rialto Smart Meter the following items are required A previously installed Rialto WhiteBox included in all Rialto Kits A mobile device smartphone tablet with Android or Apple iOS operating system Contents of the pack 1 Rialto Smart Meter 1 x Installat...

Page 15: ...products to the end of obtaining the ben efits and advantages they afford The liability of the Astrel Group in respect of its products is regulated by the Astrel Group General Conditions of Sale published on the company s website www astrelgroup com Caution The Rialto Smart Meter must be used only indoors and in dry conditions and not positioned in places exposed to high levels of humidity and or ...

Page 16: ... 16 EN Rialto Smart Meter 1 3 2 4 1 Indicator Leds 2 Button 3 Current transformer CT 4 Power cable ...

Page 17: ...alto network NOTE the Led does not indicate wireless communication status with the WhiteBox control unit the quality of the signal can be viewed on the Rialto App Operation of button table 2 Function Command Meaning First configuration Press briefly 1 second approx Addition of Smart Meter to Rialto wireless network Reset Press and hold around 20 s Restore factory settings ...

Page 18: ...d make the connections as in the diagram fig 1 3 Restore electrical power 4 Check that the indicator Led is alight red and blinking 5 Start the Rialto App select Add device to initiate the procedure that will add the Smart Meter to the Rialto network 6 Follow the guided procedure provided by the App for adding a Smart Meter to the Rialto network L L N N Load fig 1 ...

Page 19: ...ement of the new device added 9 Check that when the load household appliance to be monitored is pow ered up the Smart Meter device shows the power consumption value internally of the App CAUTION if the coverage provided by the wireless signal between the Rialto Smart Meter and the WhiteBox control unit is insufficient visit www rialtocomfort com or contact Customer Service ...

Page 20: ...plit core Current Transformer CT included Measurements Active power W active energy kWh Max measurable power 15 kW Ambient parameters Operating conditions 0 to 50 C 80 R H n c Storage conditions 20 to 70 C 80 R H n c Degree of protection IP30 Insulation Class I Degree of pollution PD2 Overvoltage category II Conformity ETSI EN 300 328 ETSI EN 301 489 1 ETSI EN 301 489 17 EN 60730 1 EN60730 2 14 ti...

Page 21: ...lares that this product is in compliance with essential requirements and other pertinent provisions established under Directive 2014 53 UE RED The declaration of conformity can be viewed at www astrelgroup com Safety and disposal Electrical and electronic equipment requiring sorted collection in compliance with local regulations on waste disposal currently in force Information and support For more...

Page 22: ...ils électriques à forte consommation d énergie Il a aussi la fonction de répéteur de signal sans fil pour les autres dispositifs Rialto installés Configurations minimales Afin d utiliser Rialto Smart Meter sont nécessaires Une Whitebox Rialto installée au préalable présente dans tous les Rialto Kit Dispositif mobile smartphone tablette avec système d exploitation Android ou Apple iOS Contenu de l ...

Page 23: ... ob tention des résultats escomptés pour chacun des produits La responsabilité d Astrel Group en ce qui concerne ses produits est régie par les conditions gé nérales de vente Astrel Group disponibles sur le site www astrelgroup com Attention Rialto Smart Meter doit être utilisé en intérieur et au sec Il faut éviter de l installer dans des endroits exposés à une forte humidité et ou aux éclaboussur...

Page 24: ... 24 FR Rialto Smart Meter 1 3 2 4 1 LED de signalisation 2 Touche 3 Transformateur d intensité TI 4 Cordon d alimentation ...

Page 25: ...OTE la LED ne donne pas d indications sur l état de communication sans fil avec l unité de commande WhiteBox la qualité du signal est visible sur l Appli Rialto Fonction touche tableau 2 Fonction Commande Signification Première configuration Pression brève env 1 sec Ajout de Smart Meter au réseau sans fil Rialto Réinitialisation Pression prolongée env 20 s Rétablissement des réglages d usine ...

Page 26: ...indiqué sur le schéma fig 1 3 Rétablissez l alimentation de l installation 4 Vérifiez que la LED de signalisation est allumée rouge clignotant 5 Lancez l appli Rialto sélectionnez Ajouter un dispositif pour com mencer la procédure d ajout de Smart Meter à votre réseau Rialto 6 Suivez l assistant de l application pour ajouter un Smart Meter à votre réseau Rialto L L N N Load fig 1 ...

Page 27: ...au dispositif ajouté 9 Vérifiez qu en mettant sous tension la charge appareil électroménager à contrôler le dispositif Smart Meter indique la valeur de puissance consommée dans l appli ATTENTION en cas de couverture insuffisante du signal sans fil entre Rialto Smart Meter et l unité de commande WhiteBox visitez le site www rialtocomfort com ou contactez le service d assistance ...

Page 28: ...is Mode de lecture TI ouvrant inclus Mesures Puissance active W énergie active kWh Puissance max mesurable 15 kW Paramètres environnementaux Conditions d utilisation 0 50 C 80 H R s c Conditions de stockage 20 70 C 80 H R s c Degré de protection IP30 Isolation Classe I Degré de pollution PD2 Catégorie de surtension II Conformité ETSI EN 300 328 ETSI EN 301 489 1 ETSI EN 301 489 17 EN 60730 1 EN607...

Page 29: ... est conforme aux exi gences essentielles et aux autres dispositions pertinentes fixées par la di rective 2014 53 UE RED La déclaration de conformité est disponible sur le site www astrelgroup com Sécurité et élimination L équipement électrique et électronique fait l objet de tri sélectif conformément aux réglementations locales en vigueur en matière d élimination des déchets Informations et assis...

Page 30: ... als Verstärker des WLAN Signals für andere installierte Rialto Geräte Mindestsystemvoraussetzungen Für die Verwendung von Rialto Smart Meter benötigen Sie Ein vorab installiertes Whitebox Rialto Steuergerät inklusive in allen Rialto Kit Ein mobiles Gerät Smartphone Tablet mit Betriebssystem Android oder Apple iOS Verpackungsinhalt 1 Rialto Smart Meter 1 Installationsanleitung 2 Schrauben 2 Dübel ...

Page 31: ...lgemeinen Geschäftsbedingungen der Astrel Group auf der Website www astrelgroup com einsehbar geregelt Warnung Rialto Smart Meter darf ausschließlich in trockenen Innenbereichen verwen det werden wobei die Installation an starker Feuchtigkeit oder Spritzwasser ausgesetzten Orten unbedingt zu vermeiden ist Wartung Trennen Sie Rialto Smart Meter zur Reinigung von der Steckdose und ver wenden Sie ein...

Page 32: ... 32 DE Rialto Smart Meter 1 3 2 4 1 Anzeige LEDs 2 Taste 3 Kabelumbauwandler 4 Netzkabel ...

Page 33: ... HINWEIS Die LED vermittelt keine Informationen zur drahtlosen Verbin dung mit dem WhiteBox Steuergerät die Signalqualität erscheint in der App Rialto Tastenfunktion Tab 2 Funktion Schaltbefehl Bedeutung Erstkonfigu ration Kurzes Drücken ca 1 Sek Hinzufügen von Smart Meter zum drahtlosen Rialto Netz Reset Langes Drücken ca 20 s Wiederherstellung der Werkseinstellungen ...

Page 34: ...lt Plan Abb 1 her 3 Schalten Sie die Versorgung der Anlage wieder ein 4 Prüfen Sie ob die LED des Geräts in Rot blinkt 5 Starten Sie die App Rialto wählen Sie Ein Gerät hinzufügen um das Hinzufügen von Smart Meter zum eigenen Rialto Netz einzuleiten 6 Führen Sie den Assistenten der App für die Kopplung eines Smart Meter mit dem eigenen Rialto Netz aus L L N N Load Abb 1 ...

Page 35: ...ng des hinzugefügten neuen Geräts auf 9 Vergewissern Sie sich dass bei Versorgung der des zu überwachenden Last Haushaltsgeräts das Gerät Smart Meter den Wert der verbrauchten Leistung in der App zeigt WARNUNG Bei unzureichender Reichweite des WLAN Signals zwischen Rialto Smart Meter und dem WhiteBox Steuergerät besuchen Sie die Websi te www rialtocomfort com oder verständigen Sie den Kundendienst...

Page 36: ...üsse Schraubklemmen Messmodus Kabelumbauwandler integriert Messungen Wirkleistung W Wirkenergie kWh Max Leistung 15 kW Umgebungsparameter Betrieb 0 50 C 80 RF n k Lagerung 20 70 C 80 RF n k Schutzart IP30 Isolation Klasse I Verschmutzungsgrad PD2 Überstromkategorie II Konformität ETSI EN 300 328 ETSI EN 301 489 1 ETSI EN 301 489 17 EN 60730 1 EN60730 2 14 Typ 1 EN 62479 EN 61000 6 2 EN 61000 6 3 P...

Page 37: ...ass dieses Produkt den Mindestanforderun gen und den anderen Vorschriften der Richtlinie 2014 53 EG RED ent spricht Die Konformitätserklärung ist auf der Website www astrelgroup com einsehbar Sicherheit und Entsorgung Elektro und Elektronikgerät das nach den geltenden Bestimmun gen zur Abfallentsorgung getrennt gesammelt werden muss Informationen und Support Für weitere Informationen und technisch...

Page 38: ...Note Notes Notes Anmerkungen ...

Page 39: ......

Page 40: ...sonzo 21 E 34070 Mossa GO Italy www astrelgroup com www rialtocomfort com 03N016010R1 0 Rialto Smart Meter Installation manual IT EN FR DE 01 06 2017 ASTREL GROUP reserves its rights to make changes or variations to its own products without any prior notice ...

Reviews: