25
1 - KING ICE operator
2 - Tuned aerial
3 - Flashing lamp
4 - Key selector
5 - Photoelectric cells (external)
* With incorporated mechanical stop that cuts in during opening. - If the mechanical stop
is used during closing (optional), the maximum travel is reduced by 50 mm.
Measurements in mm
1
to be connected to the terminal block
J7 on the T2 pc board
2
available
3
to be connected to the terminal block
J7 on the T2 pc board
free
PLUG
A
FOR CONNECTION OF
THERMAL PROBE
PLUG
B
FOR CONNECTION OF MOTOR
KING ICE L
L=1020
L1=945
L2=470
KING ICE
L=888
L1=815
L2=340
2
KING ICE has a 1 m cable
already connected to the
PROBE
1
V OPEN
2
W CLOSE
3
U COMMON
Yellow/Green
G
B
SYSTEM LAY-OUT
TECHNICAL FEATURES
KING ICE is a irreversible operator endowed with an in built heater probe,
suitable for opening gates with a leaf length of up to 5 metres (Fig. 1)even in
extremely cold areas. Thanks to its T2 control panel, KING ICE is automatically
warmed up when the temperature of the motor goes below 10°C; thus assuring
a perfect functioning even at -30°C.
The KING ICE operator use mechanical stoppers, thus avoiding the need for
electrical limit switches.
❺
❹
❶
❶
❺ ❹
❷
❸
1
TECHNICAL DATA
KING ICE
KING ICE L
Max. leaf length
m
4
5
Max. leaf weight
kg
400
500
Max. travel
mm
345*
475*
Average opening time
s.
14÷27
29÷38
Operating speed
m/s.
0,0125
Thrust force
N
1800
EEC Power supply
230V~ 50Hz
Motor capacity
W
290
Power absorbed
A
1,2
Capacitor
µF
10
Normative cycles
n°
17 - 14s/2s
10 - 33s/2s
Daily operations suggested
n°
150
Service
60%
Guaranteed consecutive cycles
n°
20/14s
15/33s
Grease
Bechem - RHUS 550
Weight of electroreducer
kg
10
14
Noise
db
<70
Volume
m
3
0,0184
0,0211
Operating Temperature
°C
-30 ÷ +55°C
Protection
IP
44