31
of time between now (stop of motor M1) and the next pressing of the PROG. button (see
step 5 below) will be then stored as waiting time for Automatic Closing feature.
5 -
Press PROG. button
, M1 closes and the Automatic Closing time is stored (see DIP3
function to enable or disable the Automatic Closing feature).
6 - The LED DL1 will turn OFF, indicating exit from the Point E procedure. Closing of the gate
will be carried out at normal speed and only on approaching total closing at low speed
(depending on the adjustment of LOW SPEED trimmer).
7 - Turn
DIP2 to OFF
position.
During Point E procedure, the safety devices (photocells and safety strip) are active.
POINT F - PROGRAMMING OF PEDESTRIAN OPENING (#)
1 - The gate must be fully closed.
2 - Turn
DIP2 to ON
position, the LED DL1 starts blinking quickly.
3 - Immediately, turn also
DIP1 to ON
position, the LED DL1 starts blinking slowly.
4 -
Press the pedestrian pushbutton PED. BUTT
, motor M1 opens
5 - When the motor M1 leaf is opened enough for the pedestrian crossing, press the
pedestrian pushbutton to stop the travel (thus defining the opening stroke of motor M1).
The gap of time between now (stop of motor M1) and the next pressing of the PROG.
button (see point 6 below) will be stored as waiting time for Pedestrian Automatic Closing
feature.
6 -
Press the pedestrian pushbutton PED. BUTT
, M1 closes and the Pedestrian
Automatic Closing time is stored (see DIP3 function to enable or disable the Automatic
Closing feature).
7 - Turn
DIP1 to OFF
position.
8 - Turn
DIP2 to OFF
position.
During Point F procedure, the safety devices (photocells and safety strip) are active.
POINT G - PROGRAMMING RADIO CODES FOR COMPLETE OPENING
(UP TO 62 CODES - ONLY FOR CRX MODELS)
You can only programme the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each, for 10
seconds.
3 - Press the remote control button (normally channel A) within the 10 seconds proscribed. If
the remote control has been correctly programmed, the DL2 LED (green) will flash once.
4 - The code programming time resets automatically so that you can programme the next
remote control.
5 - To finish programming, let 10 seconds pass and then press the PROG. button briefly. The
red DL1 LED will stop flashing.
6 - Reposition DIP 1 to OFF and DIP 2 to OFF.
7 - You have completed the procedure
PROCEDURE FOR DELETING ALL RADIO CODES USED ONLY FOR COMPLETE OPENING
You can only delete the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each, for 10
seconds.
3 - Press and hold the PROG button for 5 seconds. The green DL2 LED will flash twice to
confirm that the stored codes have been deleted.
4 - The red programming DL1 LED remains active and you can programme new codes as
shown above if required.
5 - Reposition DIP 1 to OFF and DIP 2 to OFF.
6 - You have completed the procedure.
HOW TO CHECK IF THE MEMORY IS FULL FOR RADIO CODES USED ONLY FOR
COMPLETE OPENING
You can only check the memory if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The green DL2 LED will flash 6 times if the memory is full (64 codes have been stored).
3 - After this, the DL1 programming LED will remain active for 10 seconds, so that you can
delete all codes if required.
4 - Reposition DIP 1 to OFF and DIP 2 to OFF.
5 - You have completed the procedure
POINT H - PROGRAMMING RADIO CODES FOR PEDESTRIAN OPENING
(UP TO 62 CODES - ONLY FOR CRX MODELS)
You can only programme the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 3 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each, for 10
seconds.
3 - Press the remote control button (normally channel B) within the 10 seconds proscribed. If
the remote control has been correctly programmed, the DL2 LED (green) will flash once.
4 - The code programming time resets automatically so that you can programme the next
remote control.
5 - To finish programming, let 10 seconds pass and then press the PROG. button briefly. The
red DL1 LED will stop flashing.
6 - Reposition DIP 1 to OFF and DIP 3 to OFF.
N.B: IF THE DL1 LED CONTINUES TO FLASH RAPIDLY, THIS MEANS THAT DIP 1 IS
STILL POSITIONED TO ON AND ANY MANOEUVRE HAS BEEN DELETED.
7 - You have completed the procedure.
PROCEDURE FOR DELETING ALL RADIO CODES USED ONLY FOR COMPLETE OPENING
You can only delete the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 3 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each, for 10
seconds.
3 - Press and hold the PROG button for 5 seconds. The green DL2 LED will flash twice to
confirm that the stored codes have been deleted.
4 - The red programming DL1 LED remains active and you can programme new codes as
shown above if required.
5 - Reposition DIP 1 to OFF and DIP 3 to OFF.
6 - You have completed the procedure.
HOW TO CHECK IF THE MEMORY IS FULL FOR RADIO CODES USED ONLY FOR
COMPLETE OPENING
You can only check the memory if the gate is closed.
1 - Position DIP 1 to ON and then DIP 3 to ON.
2 - The green DL2 LED will flash 6 times if the memory is full (64 codes have been stored).
3 - After this, the DL1 programming LED will remain active for 10 seconds, so that you can
delete all codes if required.
4 - Reposition DIP 1 to OFF and DIP 3 to OFF.
5 - You have completed the procedure.
FUNCTIONING OF CONTROL ACCESSORIES
ATTENTION: ONLY IMPULSIVE COMMANDS HAVE TO BE CONNECTED.
Make sure that any other type of command accessories (e.g. mass detectors) used on
the installation are set in the IMPULSIVE mode, otherwise, the gate will be operated
even without the protection of the safety devices.
STEP BY STEP or AUTOMATIC commands
(K BUTT button, PED BUTT button, RADIO REMOTE button)
DIP 6 - OFF
The K BUTT, the PED BUTT button, the RADIO REMOTE buttons perform the
cyclic command open-stop-close-open-stop-etc.
DIP 6 - ON
The K BUTT, the PED BUTT button, the RADIO REMOTE buttons perform:
- the open command, if pressed with the gate completely closed
- the close command, if pressed with the gate completely opened
- no effect, if pressed during the gate opening
- the gate re-open, if pressed while the gate is closing
The K BUTT opens the gate completely, whereas the PED BUTT opens the gate partially as
described in Point F.
CLOCK FUNCTION
If you want the Clock Function must request T2 with firmware NOUP 14.
ATTENTION: A CLOCK CONNECTED TO T2 with fw 09 or more ACTIVATES THE
AUTOMATIC MOVEMENT OF THE GATE WITHOUT HAVING THE PROTECTION OF
THE SAFETY DEVICES!
The Clock Function is useful during rush hours, when traffic is heavy and the flow is slow (e.g.
entrance/exit of employees, emergencies in residential areas or car parks and, temporarily,
for removal vans) and it’s necessary to keep the gate opened.
CLOCK FUNCTION APPLICATION
It is necessary to request a T2 control panel with firmware NOUP 14.
Select the automatic functioning DIP 6 ON.
It can be done by connecting a switch and/or a daily/weekly clock either in parallel to the K
BUTT button or instead of the K BUTT button. When the control board receives this command,
the gate will open and by keeping this contact closed for all the time of the gate opening, the
Clock Function is automatically activated. In fact, once reached the open position, the gate
will remain opened and all of the control board functions are blocked. Only when K BUTT
contact is released, the control board functions are re-activated and the Automatic Closing
restarts (if enabled) doing the countdown to the gate closing.
PEDESTRIAN command (PED BUTT - COM)
This command is useful to open the gate partially, just enough, for example, to permit a
pedestrian crossing. In fact, the Pedestrian command (see Point F) is carried out only by
opening the motor M1 just enough for a pedestrian to pass, as described into the Point F
G
B