18
G
B
TECHNICAL CHARACTERISTICS
- Reversible gearmotor for intensive use used to move long booms up to 3 m.
- The maintenance unit is lubricated by oil bath and requires no maintenance.
- The barrier is equipped with a logic controller, inverter, electric proximity limit switches and
mechanical stops.
- HIGHWAY is the first barrier in the world equipped with a boom with a motorized joint for
automatic release of the boom following a violent impact (patent No. EP2642028).
- Opening/closing time can be adjusted from 0.8s to 6.3s.
- It is equipped with a balancing spring, tested for 5,000,000 cycles.
- HIGHWAY is three-phase 220V with 100% service to control vehicular traffic at highway toll
stations and large parking lots.
- In the absence of current, the boom will lift automatically without any staff intervention.
- The boom can be made of Carbon with foam for shock absorption and a Ø80 protective
cover with reflective strips.
- Electronic brake in combination during opening and closing.
- Equipped with PLC control unit and inverter for maintaining the closed position and boom
movement management.
- The PLC control unit allows you to connect magnetic sensors, open/close separate controls,
photocells, automatic closing that can be deactivated by switch, etc.
- Proximity sensor for transmission speed, limit switch and detection of boom uncoupling
following an impact.
- Boom uncoupling in the operating direction without return rebound and with a boom that
can absorb the impact (for carbon boom).
- IP54 degree of protection.
- Average time from use without maintenance 15,000 hours.
- Steel structure protected by cataphoresis treatment and thermoset coating
N.B.
It is obligatory to standardize the characteristics of the system to the rules and laws
in force.
TECHNICAL CHARACTERISTICS
HIGHWAY
DX Cod.AA50600
SX Cod.AA50605
Max. boom length
2 m
Carbon
Code ACG8620
2,5 m
Carbon
Code ACG8621
3 m
Carbon
Code ACG8622
3 m Ø=80
Aluminum
Code ACG8501
Spring unit
RED (CTC1392)
YELLOW (CTC1399)
Default opening time
1,2 s open / 1,7 s close *
Power supply and frequency
230V 50-60 Hz
Max. motor power
460 W
Max. motor absorption
2 A
Max. torque on the boom holder shaft
86 Nm
Regulatory Cycles
∞
- 1s/1s
Service
100%
Max. Weight
kg 55 without box, spring, hub and boom
Work temperature
-10 + 55 °C
Protection rating
IP 54
** Automatic reset unit
YES
NO
Hub for reset
ACG4020DX - ACG4020SX
NO
Aluminium Hub for boom
NO
ACG8627
Power consumption in stand-by 230V 50 Hz
0,35 A
Power consumption while working 230V 50 Hz
0,6 A
1,2 A
1,8 A
1,8 A
Power consumption in reset 230V 50/60 Hz
2,0 A
-
Power consumption in stand-by 230V 60 Hz
0,5 A
Power consumption while working 230V 60 Hz
0,8 A
1,4 A
2,0 A
2,0 A
* These are the times detected with a 2m carbon boom, factory setting of inverter frequency and slow downs of the movement of the boom enabled in combination.
** The automatic reset unit is only applicable to carbon booms.
It is a motorized device (230Vac) controlled by a sensor that detects the release of the boom.