17
11
10
N
L
230Vac o/ou/or 120Vac
17
18
GND
ANT
16
15
L
N
LIGHT
14
13
12 U
W
V
L
L
N
MOT
OR
2
1
COM
STOP
2
3
COM
OPEN
2
4
COM
CLOSE
COM
2
PHOTO
5
6
7
+
-
24Vdc
3. Electrical connections
The control unit is supplied with all the inputs normally closed and jumpered to the common.
Before connecting a device to the control unit remove the jumper corresponding to the device that you want to connect leaving the others unchanged.
Connect the power supply cable between the clamps 10 and 11
of the control unit.
Connect the aerial cable.
Central wire to terminal 18
Shield to terminal 17
Power supply 230 Vac 50 Hz (Optional 120 Vac 60 Hz)
Do not connect the card directly to the electric network.
Put a device which can ensure the disconnection of each pole from
the power supply of the control unit.
A piece of wire is already present in terminal 18, and this can
guarantee an acceptable range for the radio signal.
Connect an eventual courtesy light between the clamps 15 and
16 of the control unit.
Connecting a charge of 230Vac (or 120Vac) 500W MAX it is possible
to light up the operating zone of the automation during each motion.
The turning off is timed with a period of
3 minutes.
The counting is reset at each impulse of up or down.
4. Signalling led
• Connect the neutral of the motor to the clamp 12 “U” of the
control unit.
• Connect the phase “1” of the motor to the clamp 13 “W” of
the control unit.
• Connect the phase “2” of the motor to the clamp 14 “V” of the
control unit.
Connect the
NORMALLY CLOSED
contact of the STOP to the
clamp 1 and 2 of the terminal board.
WARNING : jumper the input 1 to the input 2 if not used.
Check that the motor wiring is compliant with the installation.
To do this, follow the procedure of the
preliminary checks
.
If the STOP input is open, then this causes the immediate stop of
the automation
Connect the OPEN button between the clamp 2 and 3 of the
terminal board.
Leave it opened if not used.
The activation of the OPEN button gives an opening impulse to the
automation.
Connect the CLOSE button between the clamp 2 and 4 of the
terminal board.
Leave it opened if not used.
The activation of the CLOSE button gives a closing impulse to the
automation.
Connect the
NORMALLY CLOSED
contact of the photocell
(PHOTO) between the clamp 2 and 5 of the control unit.
WARNING: jumper the input 2 to the input 5 if not used.
Connect the power supply of the accessories to the clamp 6 and
7 of the terminal board.
“Power On”: lighted when the control unit is powered.
“Photo”: lighted if the photocell contact is closed.
The PHOTOCELL (PHOTO) can cause the STOP of the automation
or the motion inversion .
See chap.9
WARNINGS
: the control unit gives a voltage of 24 Vdc.
“Stop”: lighted if the contact stop is closed.
G
B