30
MECHANICAL STOP - OPTIONAL
Code ACG8089
Optional mechanical stop to stop closing, if the gate is not fitted with a floor stop (Fig. 8).
MECHANICAL STOPPER ADJUSTMENT
To adjust the stoppers you have to follow the scheme (Fig. 9).
To set the opening limit it’s enough to fix the stopper (A) in the needed position by
tightening the 8mA screw with a n. 13 key.
To obtain the desired closing limit you must adjust the stopper (B) (OPTIONAL) ) in the
needed position and tighten it as for stopper (A).
MAINTENANCE
To be undertaken only by specialized staff after disconnecting power supply.
Lubricate the hinges and check the oil level and thrust force generated by the operator
on the gate once a year.
Lubricate the nut screw with silicon grease every two years.
9
8
10
G
B