background image

Cod. CVA2247 - 10032015 - Rev. 15

8 028265 128521 >

KIT KING 24V

Questo prodotto è stato completamente progettato e costruito in Italia · Ce produit a été complètement développé et fabriqué en Italie · This product has been 
completely developed and built in Italy · Dieses Produkt wurde komplett in Italien entwickelt und hergestellt · Artìculo totalmente proyectado y producido en Italia

  25014 CASTENEDOLO (BS) - ITALY

Via Matteotti, 162

Tel. +39.030.2135811

Fax +39.030.21358279

www.ribind.it - ribind@ribind.it

automatismi per cancelli

automatic entry systems

®

Codice

Denominazione Particolare

ACG1082

Chiave di sblocco

ACG8089

Gruppo Fermo meccanico di chiusura OPT

BA01019

Serie accessori per cilindro KING

BA10052

Gruppo Chiocciola serie KING

BA10065

Gruppo semig. sup. KING completo

BA101024V Connettore con cavo
CAL1160

Semiguscio inferiore KING 

CCA1294

Piatto colonna regolabile

CCA1351

Attacco cancello serie KING

CCA1355

Angolare attacco a colonna (2 pezzi) 

CCA1379

Forcella posteriore in acciaio

CCM6005ZZ Cuscinetto motore 6005ZZ
CEL1425

Condensatore 10µF 450V x serie 230V/50

CEL1426

Condensatore 35µF 450V x serie 120V/60

CME1166

Adattat. motore KING 24V

CME1299

Perno per ingranaggio serie KING

CME2042

Corona elicoidale sblocco sx

CME2041

Corona elicoidale dx serie KING

CME8996

Vite s/fine KING 12/24V

CME9130

Vite madre KING 

CME9785

Perno Sblocco serie KING

CME9868

Perno di traino serie KING

CMO2515

Motore KING 24V fino alla matricola 1185165 
+ il cod. BA02515C

CMO2515C Motore KING 24V dalla matricola 1185166
CPL1087

Ingranaggio conico

CPL1157

Tappo per fermo meccanico serie KING

CPL1161

Ingranaggio conico serie KING

CRS62042R Cuscinetto 6204/2RS
CTC1004

Chiavetta 6 6 12

CTC1008

Chiavetta 6 6 30

CTC1119

Seeger E17

CTC1120

Seeger E20

CTC1123

Seeger E25

CTC1158

Spina elettrica 5 20

CTC1214

Spina cilindrica 8x32

CTC1258

Molla per sblocco serie KING

CTC1259

Molla trazione coperchio serie KING

CTC1303

Anello di tenuta OR 158

CTC1307

Anello di tenuta OR2037

CVA1176

Boccola 12x16x12 Bronzo F7/R7

CVA1325

Cilindretto per serratura serie KING

DDD10MAI

Dado Autob. M10 Alto Inox

DRL10X20I

Rondella Piana 10X20 Inox

DRL10X30I

Rondella Piana 10X30 Inox

DRL12X24Z Rondella Piana 12X24
DTB6X35

Vite TCEI M6x35 zinc.

DTC55X50Z Vite TC Croce 5,5x50
DTE10X20I

Vite TCEI 6X30 Inox UNI5931

DTE8X30I

Vite TE 8X30 Inox UNI5739

DTM10X40I Vite TE 10X40 Inox UNI 5737

Summary of Contents for AD00709

Page 1: ...erator Torantrieb Operador Alimentazione Alimentation Power Supply Stromspannung Alimentacion Peso max cancello Poids maxi portail Max gate weight Max Torgewicht Peso m x verja Forza max di spinta For...

Page 2: ...cati dalla mancata osservanza nell installazione delle norme di sicurezza e delle leggi attualmente in vigore ATTENTION POUR LA SECURITE DES PERSONNES IL EST IMPORTANT DE SUIVRE TOUTES LES INSTRUCTION...

Page 3: ...es caused by the non observance during the installation of the safety standards and of the laws in force at present ACHTUNG F R DIE SICHERHEIT DER PERSONEN IST ES WICHTIG DASS ALLE ANWEISUNGEN GENAU A...

Page 4: ...normas EN 12453 EN 12445 4 El instalador antes de instalar el motor de desplazamiento tiene que controlar que la cancela est en buenas condiciones mec nicas y que se abra y se cierre en forma adecuad...

Page 5: ...ntenna radio 3 Lampeggiatore 4 Selettore a chiave 5 Fotocellule esterne 1 NERO 1 Collegare a J5 o J6 morsetto NERO 2 Collegare a J5 o J6 morsetto CARATTERISTICHE TECNICHE KING 24V Lunghezza max anta m...

Page 6: ...orze entro i limiti della norma EN12453 Appendice A E Fotocellule es cod ACG8026 Da applicare ogni 60 70cm per tutta l altezza della colonna del cancello fino ad un massimo di 2 5m EN 12445 punto 7 3...

Page 7: ...ANT COL 1 1 80 90 45 100 100 815 90 14 A S3 Y 1 81 2 20 45 110 110 815 90 18 A S3 X 2 21 2 50 70 140 110 815 90 20 A S1 Z 2 51 3 00 90 170 140 815 115 25 B S2 Y 3 01 3 50 115 200 140 815 115 27 B S2...

Page 8: ...ermo A e bloccarlo serrando la vite da 8mA con una chiave fissa n 13 Per ottenere la chiusura desiderata si dovr spostare il fermo B OPZIONALE bloccandolo come descritto per il fermo A MANUTENZIONE Da...

Page 9: ...PASSO COMUNE COMUNE 24Vdc 0 8A 15 per ACCESSORI 24Vdc 0 8A 15 per AUTOTEST COSTE LAMPEGGIATORE 24Vdc 20W LED R 2 2K 1 4W SERRATURA ELETTRICA PEDONALE COSTE ALIMENTAZIONE 230Vac 50Hz TRASFORMATORE M1...

Page 10: ...a NON TOCCARE IL PONTICELLO SE VIENE RIMOSSO L OPERATORE NON FUNZIONA Connettore dedicato alla programmazione in fabbrica solo per modelli CRX NON TOCCARE IL PONTICELLO SE VIENE RIMOSSO L OPERATORE NO...

Page 11: ...so DL6 segnalazione tempo chiusura automatica rosso DL7 contatto fotocellule NC rosso DL8 contatto costa NC rosso DL9 comando pulsante STOP NC rosso DL10 programmazione codici radio verde FUSIBILI Fus...

Page 12: ...a cancello fermo 1 Posizionare il DIP 1 su ON e successivamente il DIP 2 su ON 2 Il led rosso DL1 di programmazione lampeggia con frequenza di 1 sec ON e 1 sec OFF per 10 secondi 3 Premere e mantenere...

Page 13: ...condo anche se le stesse restano impegnate GESTIONE CHIUSURA IMMEDIATA DOPO IL TRANSITO DA FOTOCELLULE DIP 16 ON e DIP 4 OFF Mentre il cancello apre transitando davanti alle fotocellule il cancello si...

Page 14: ...24VDC Potenza Trasformatore 130VA primario 230Vac secondario 18Vac Assorbimento massimo 50 mA Microinterruzioni di rete 100ms Potenza massima spia cancello aperto 24Vdc 3W equivalente a 1 lampadina d...

Page 15: ...CH cod ACG6058 TELECOMANDO SUN DISPOSITIVI Wi Fi NOVA Wi Fi FOTOCELLULE SENZA FILI cod ACG8037 COPPIA COLONNINE NOVA cod ACG8039 VERTIGO Wi Fi FOTOCELLULE SENZA FILI SOSTITUTIVE DELLA COSTA VERTIGO Wi...

Page 16: ...de 50 mm 1 Operateur KING 24V 2 Antenne radio 3 Signal electrique 4 Selecteur 5 Photocellules p protection externe 1 NOIR 1 Connecter J5 ou J6 borne NOIR 2 Connecter J5 ou J6 borne CARACTERISTIQUES TE...

Page 17: ...spositifs de limitation des forces dans les limites de la norme EN12453 appendice A E Cellules photo lectriques code ACG8026 Appliquer chaque 60 70 cm pour toute la taille de la colonne de la porte ju...

Page 18: ...sec ANT COL 1 1 80 90 45 100 100 815 90 14 A S3 Y 1 81 2 20 45 110 110 815 90 18 A S3 X 2 21 2 50 70 140 110 815 90 20 A S1 Z 2 51 3 00 90 170 140 815 115 25 B S2 Y 3 01 3 50 115 200 140 815 115 27 B...

Page 19: ...e il suffit de d placer le collier A et de le bloquer en vissant la vis M8 avec une cl n 13 Pour obtenir la fermeture desir e il est necessarie de deplacer le collier B OPTIONAL et de le bloquer comme...

Page 20: ...PAS COMMUN COMMUN 24Vdc 0 8A 15 pour ACCESSOIRES 24Vdc 0 8A 15 AUTOTEST pour BARRE PALPEUSE FEU CLIGNOTANT 24Vdc 20W LED R 2 2K 1 4W SERRURE LECTRIQUE PIETON BARRE PALPEUSE ALIMENTATION 230Vac 50Hz TR...

Page 21: ...en usine NE PAS TOUCHER AU CAVALIER SANS L OP RATEUR IL NE FONCTIONNE PAS Connecteur d di la programmation en usine seulement pour les mod les CRX NE PAS TOUCHER AU CAVALIER SI LE SYST ME RADIO EST E...

Page 22: ...ement ou partiellement ouverte pi tonne et avec la DEL DL6 allum e le trimmer doit tre r gl dans le sens des aiguilles d une montre Le temps de pause peut varier de 2 secondes 2 minutes selon le r gla...

Page 23: ...A PROGRAMMATION CHOISIE E PROGRAMMATION DES CODES RADIO POUR OUVERTURE TOTALE 62 CODES MAXIMUM UNIQUEMENT POUR LES MODELES CRX La programmation ne peut se faire que lorsque le portail est ferm 1 Posit...

Page 24: ...s ouvrir stopper fermer stopper ouvrir etc Si DIP 6 est sur ON Il effectue l ouverture quand le portail est ferm S il est actionn pendant le mouvement d ouverture cela ne produit aucun effet S il est...

Page 25: ...ommande et la fermeture automatique sont de travail Note 1 Au cours de cette op ration dans le cas de panne de les barres palpeuses ou cellules photo lectriques les cellules photo lectriques ou barres...

Page 26: ...PHOTOCELLULES SANS FIL POUR REMPLACER LA BARRE PALPEUSE VERTIGO Wi Fi 8 code ACG8042 VERTIGO Wi Fi 10 code ACG8043 BLOCK Wi Fi S LECTEUR CL SANS FILS code ACG6098 SPARK Wi Fi FEU CLIGNOTANT SANS FILS...

Page 27: ...stop is used during closing optional the maximum travel is reduced by 50 mm 1 KING 24V operator 2 Tuned aerial 3 Flashing lamp 4 Key selector 5 Photoelectric cells external 1 TECHNICAL DATA KING 24V...

Page 28: ...keep thrust force within the limits of EN12453 regulation Appendix A E Photocells like code ACG8026 To apply every 60 70cm for all the height of the column of the gate up to a maximum of 2 5m EN 12445...

Page 29: ...COL 1 1 80 90 45 100 100 815 90 14 A S3 Y 1 81 2 20 45 110 110 815 90 18 A S3 X 2 21 2 50 70 140 110 815 90 20 A S1 Z 2 51 3 00 90 170 140 815 115 25 B S2 Y 3 01 3 50 115 200 140 815 115 27 B S2 Y L M...

Page 30: ...per A in the needed position by tightening the 8mA screw with a n 13 key To obtain the desired closing limit you must adjust the stopper B OPTIONAL in the needed position and tighten it as for stopper...

Page 31: ...P COMMON COMMON 24Vdc 0 8A 15 for ACCESSORY SUPPLY 24Vdc 0 8A 15 for AUTOTEST SAFETY STRIPS BLINKER 24Vdc 20W LED R 2 2K 1 4W ELECTRIC LOCK PEDESTRIAN SAFETY STRIPS POWER SUPPLY 230Vac 50 Hz TRANSFORM...

Page 32: ...DO NOT REMOVE ANY JUMPER OTHERWISE THE OPERATOR WILL NOT WORK Connector dedicated to the factory programming only CRX control board DO NOT REMOVE ANY JUMPER OTHERWISE THE OPERATOR WILL NOT WORK Built...

Page 33: ...pening M1 green DL5 gate closing M1 red DL6 automatic closing indicator red DL7 photocell contact NC red DL8 sensor contact NC red DL9 STOP button NC red DL10 radio code program green FUSES Fuse 1 T 8...

Page 34: ...ellation is indicated by two flashes of green LED DL10 4 The red LED DL1 remains active and you can add new codes as shown above 5 Reset DIP 1 to OFF and DIP 2 to OFF 6 End of procedure INDICATOR MEMO...

Page 35: ...when closing If engaged when closing reverses the motion when opening If it remains engaged again it performs a further reversal after 2 seconds then performs an additional short reversal and then gi...

Page 36: ...power to the board and is set up to ensure compliance with double or reinforced insulation with regard to dangerous voltage Any external circuits connected to the outputs of the control panel must be...

Page 37: ...TRANSMITTER SUN Wi Fi DEVICES MASTER Wi Fi RECEIVER CARD TO MANAGE WIRELESS SYSTEM with connector 12 30V ac dc code ACG6094 with terminal block 12 30V ac dc code ACG6099 NOVA Wi Fi PHOTOCELLS WITHOUT...

Page 38: ...HE EIGENSCHAFTEN KING 24V Max Torfl gelweite m 4 Max Torgewicht kg 400 Max Hub mm 345 ffnungszeit ca s 14 27 Laufgeschwindigkeit m s 0 0125 Max Schubkraft N 1800 Stromspannung und Frequenz 24V 24V Mot...

Page 39: ...ungen muessen mit den Norm EN12453 uebereinstimmen Anhang A E Photozelle wie Kode ACG8026 Jede 60 70 cm f r die ganze H he der Spalte des Gatters bis zu einem Maximum von 2 5 m anwenden EN 12445 Punkt...

Page 40: ...Max a A max B C D E T sec ANT COL 1 1 80 90 45 100 100 815 90 14 A S3 Y 1 81 2 20 45 110 110 815 90 18 A S3 X 2 21 2 50 70 140 110 815 90 20 A S1 Z 2 51 3 00 90 170 140 815 115 25 B S2 Y 3 01 3 50 115...

Page 41: ...w nschte Offnungsweite einzustellen gen ngt es die Endschalter A zu verstellen und sie mit Hilfe eines Imbusschl els an der Mutterschraube festzuziehen Um die erw nschte Schliessweite einzustellen m s...

Page 42: ...EINSAME ERDUNGSKONTAKTE GEMEINSAME ERDUNGSKONTAKTE 24Vdc 0 8A 15 f r ZUBEH RE 24Vdc 0 8A 15 f r AUTOTEST KONTAKTLEISTE BLINKER 24Vdc 20W LED R 2 2K 1 4W ELEKTROSCHLOSS FUSSG NGER KONTAKLEISTE STROMVER...

Page 43: ...f r die Programmierung in der Fabrik NICHT DIE BERBR CKUNG BER HREN OHNE ANTRIEB NICHT BETRIEBSF HIG Verbinder f r die Programmierung in der Fabrik nur f r die Modelle CRX NICHT DIE BERBR CKUNG BER H...

Page 44: ...g ffnung und eingeschalteter LED Anzeige DL6 Trimmer im Uhrzeigersinn gedreht Die Pause kann von mindestens 2 Sekunden bis maximal 2 Minuten eingestellt werden LED ANZEIGEN DL1 Programmierung aktivier...

Page 45: ...eschlossenem Tor 1 DIP 1 auf ON und anschlie end DIP 2 auf ON stellen 2 Die rote LED AnzeigeDL1 f r die Programmierung blinkt mit einer Frequenz von 1 Sek ON und 1 Sek OFF f r 10 Sekunden 3 Die Fernst...

Page 46: ...enem Tor gedr ckt so wird das Tor geschlossen dr ckt man sie bei geschlossenem Tor f hrt das zur ffnung ELEKTRISCHE VERRIEGELUNG LOCK DIP 8 auf ON stellen um den Befehl f r die elektrische Verriegelun...

Page 47: ...rend dieses Vorgangs im fall eines ausfalls der Kontaktleisten oder Fotozellen der Fotozellen oder Kontaktleisten funktionieren noch Unterbrechung des Betriebs im Gange Anmerkung 2 Die Stoppen Taste i...

Page 48: ...G6058 FERNSENDER SUN Wi Fi VORRICHTUNGEN MASTER Wi Fi KARTE F R DEN BETRIEB DES SYSTEMS OHNE KABEL mit Verbinder 12 30V ac dc Kode ACG6094 mit Endblockierung 12 30V ac dc Kode ACG6099 NOVA Wi Fi FOTOZ...

Page 49: ...lo mec nicos Con el seguro mec nico incorporado que interviene durante la abertura Si se utiliza tambi n el seguro mec nico que interviene durante el cierre opcional la carrera m xima de remolque se r...

Page 50: ...Regulacion de la fuerza del motor D Nervaduras como c d ACG3010 y o otros dispositivos que limitan las fuerzas entre limites de las normas EN 12453 Appendix A E Fotoc lulas como c d ACG8026 Da applic...

Page 51: ...D E T sec ANT COL 1 1 80 90 45 100 100 815 90 14 A S3 Y 1 81 2 20 45 110 110 815 90 18 A S3 X 2 21 2 50 70 140 110 815 90 20 A S1 Z 2 51 3 00 90 170 140 815 115 25 B S2 Y 3 01 3 50 115 200 140 815 11...

Page 52: ...y bloquearlo con una llave fija n 13 Para poder obtener el cierre deseado se tendr que mover el seguro B OPCIONAL y bloquearlo con una llave fija n 13 MANTENIMIENTO Estas operaciones deben ser efectu...

Page 53: ...O PASSO COM N COM N 24Vdc 0 8A 15 para ACCESSORIOS 24Vdc 0 8A 15 para AUTOTEST COSTAS INTERMITENTE 24Vdc 20W LED R 2 2K 1 4W CERRADURA EL CTRICA PEATONAL COSTAS ALIMENTACION 230Vac 50Hz TRANSFORMADOR...

Page 54: ...O RESPETAR LAS PRUEBAS DE IMPACTO INDICADAS EN LA NORMATIVA EN12453 EN CASO DE QUE NO SEA NECESARIO OBEDECER LA NORMA ARRIBA DESCRITA BASTA COLOCAR EL DIP 3 EN POSICI N OFF EN ESTE CASO LAS PUERTAS SE...

Page 55: ...LOS TIEMPOS PARA 1 MOTOR M1 CON SENSOR DE CORRIENTE HABILITADO DIP 7 ON ATENCI N PARA GESTIONAR UN SOLO MOTOR EL DIP 13 DEBE ESTAR COLOCADO EN POSICI N ON DURANTE LA PROGRAMACI N EL SENSOR DE CORRIEN...

Page 56: ...os est n programados en el modo de IMPULSO de lo contrario pueden activar el movimiento de la puerta sin tener activos los elementos de seguridad PULSADOR DE MANDO PASO PASO COM K BUTTON Si DIP 6 en O...

Page 57: ...de seguridad se estropea o se queda empe ada por mas de 60 segundos los comandos ABRE CIERRE K BUTTON y el PEATONAL funcionar n solo a hombre presente El signal de activaci n de este funcionamiento se...

Page 58: ...CH c d ACG6058 TELEMANDO SUN DISPOSITIVOS Wi Fi MASTER Wi Fi FICHA DE GESTI N SISTEMA SIN CABLES con enchufe 12 30V ac dc c d ACG6094 con regleta 12 30V ac dc c d ACG6099 NOVA Wi Fi FOTOC LULAS SIN CA...

Page 59: ...2 de la Directive machines 2006 42 CEE et de ses modifications successives Sa mise en service est interdite avant que l installation ait t d clar e conforme aux dispositions pr vues par la Directive T...

Page 60: ...nsatore 35 F 450V x serie 120V 60 CME1166 Adattat motore KING 24V CME1299 Perno per ingranaggio serie KING CME2042 Corona elicoidale sblocco sx CME2041 Corona elicoidale dx serie KING CME8996 Vite s f...

Reviews: