background image

25

the battery. The functioning of the bar is ensured up to a voltage level of 
about 20V, after which we have a signalling given by the recharge card 
of the gearcase which blocks the bar and makes the battery state pilot 
light lighten. Once the network voltage is back, the recharge card starts 
charging the battery and the battery state led switches off. It is sufficient to 
press the remote control (or the opening button 1 or 2 or the step by step 
button ) to open the bar. When the bar is open, give a closing command 
or wait the pause time before the automatic closing => the bar starts 
closing. When closed, the normal functions are reactivated. 

DIP 9 - ON =>   

with lack of network voltage the bar opens automatically, the battery state 
led switches on and all controls are inhibited. When the network voltage is 
back, the bar closes immediately thus resetting the controls and safeties 
functioning. 

IN CASE NO BATTERY IS CONNECTED

, through the DIP 10 you can have the following 

options:

DIP 10 - OFF => 

 In lack of the network voltage the bar stays still or, in case it is moving, it 
stops. Once the network voltage is back, it is sufficient to press the remote 
control, 1 and 2 OPENING buttons or step by step button to open the bar. 
When the bar is open, give a closing command or wait the pause time 
before the automatic closing => The bar starts closing => When closed, 
the normal functions are reactivated. During the realignment the securities 
are active.

DIP 10 - ON => 

 At the return of the network voltage the bar closes if open, and doesn’t 
close only in case the clock function is active. (see OPENING 1 button).

SAFETY FITTINGS OPERATION

SECURITY LOCK 

For a correct functioning of the system, the DL4 led must always be on to signal that the 
manual release has not been activated. If the DL4 led is off no movement of the bar is allowed 
because it has been manually released with the special key. 

ENCODER

It has the duty to act as security and to define the running, both during the closing and the 
opening phase, with reversal of the movement.
It is possible to exclude the ENCODER, which only functions as security, through DIP 7 (OFF). 
In case the ENCODER should not work (not fed, disconnected wires or faulty) the movement 
of the bar is not carried out. 
If after a first intervention of the ENCODER in closing or opening phase there is a second one, 
obviously in the contrary sense, the bar stops and then reverses for 1 sec. The bell (buzzer 
optional) will be activated to signal the alarm state for 5 minutes and the flashlight will be 
active for a minute. 
During or after the 5 minutes of sounding alarm (buzzer optional), it is possible to reset the 
functioning of the bar by pressing any control button. 

PHOTOELECTRIC CELL  (terminals 3-4)

When the bar is down, if there is an obstacle in the radium of the photoelectric cells and 
the opening command is given, the bar opens (during the opening phase the photoelectric 
cells will not work).
The photoelectric cells will only work during the closing phase (with reset of the reverse 
motion after a second even if they are busy). 

N.B.:  Every six months make sure to check that photocells are not out of order.
ATTENTION: In case the receiver led remains lit, 
malfunctioning of the main supply is suspected. 
It is advisable to connect electrically the photocells stands 
to the contact 10, to shield the photocells from external 
noise.
Be careful not to short circuit the system when the supply 
phases are inverted!

STOP BUTTON (terminals 3-5)

During whatever operation the STOP button stops the bar. 
If pressed when the bar is completely open the automatic closing is temporarily excluded (if 
selected through DIP3). It is thus necessary to give a new command to make it close again.
At the following cycle the automatic closing function is reactivated (if selected through DIP3).

FLASHLIGHT (terminals 9 positive / 13 negative)
N.B.:  This electronic board can feed ONLY FLASHLIGHTS WITH LIGHTENING CIRCUIT 

and a 24V lamp. 

The flashlight is active during the motion of the bar, or to signal the impact alarm state for 

1 minute. 
Use a flashlight (code ACG7061) with a max. 24V 20W lamp.

BUZZER (Optional - terminals 3 positive / 12 negative)

During the opening and the closing phase the buzzer will give a sounding intermittent signal.
In case of intervention of the securities (alarm) this sounding signal increases the frequency 
of the intermittence. 
Power provided for the functioning of the 200mA buzzer at 12Vdc.

TECHNICAL CHARACTERISTICS

- Humidity  

 < 95% without condensation

- Feeding tension 

230V~ ±10%

- Frequency  

50/60 Hz

- Battery feeding   

20-24,5Vdc

- Transformer power 

 130VA - V primary 230 Vac - V 
Secondary 18Vac

- Standby modus 

100mA

- Network micro interruptions   

100ms

- Flashlight max. load  

24Vdc 20W

- Power available for  per photoelectric cells and fixtures
 

1A ±15% 

- Power available on radio connector  

200mA  

-  All the inputs must be used as clear contacts because the power supply is generated inside 

(safe power) the control panel, and it has been laid down in such a way to guarantee a 
double or strengthened insulation  in relation to the parts with dangerous power. 

-  Eventual external circuits connected to the outputs of the control board or of the expander 

card must be carried out making sure that a double or strengthened insulation is used in 
relation to parts with dangerous power.

-  All inputs are run by a programmed integrated circuit which does a self check every time 

it starts operating.

TROUBLE SHOOTING

After having carried out all connections, by carefully following the layout and having 
positioned the bar in intermediate position, check the correct ignition of LEDS DL2, DL3, DL4; 
the led DL1 can be ignited or extinguished.
In case of no ignition of the LEDS, always with bar in intermediate position, check the 
following and replace any faulty components.
DL1 

switched off 

Faulty Encoder 

DL2 

switched off 

Faulty Stop button

DL3 

switched off 

Faulty photocells

DL4 

switched off 

Faulty manual release or unblocked bar.

During functioning with personnel present, with DIP 1 at ON, check that during opening the 
green DL6 LED switches on and that during closing the red DL7 LED switches on. If not, 
invert the wires of the motor.

24Vdc

Cont.

10

G

B

Summary of Contents for PRESIDENT

Page 1: ...ERSIBLE PARA CONTROL DE TRÁFICO VEHICULAR ITALIANO pag 05 FRANÇAIS pag 13 ENGLISH page 21 DEUTSCH pag 29 ESPAÑOL pag 37 Operatore Operateur Operator Torantrieb Operador Alimentazione Alimentation Power Supply Stromspannung Alimentacion Lunghezza max asta Longueur maxi de la lisse Max boom lenght Max Baumlänge Longitud máxima de la asta Codice Code Code Code Codigo PRESIDENT 3M 230V 50 60Hz 3 m AA5...

Page 2: ...t de celle ci un interrupteur de type magnéto thermique omnipolaire avec ouverture minimum des contacts égale à 3 mm qui porte la marque de conformité aux normes internationales Ce dispositif doit être protégé contre la re fermeture accidentelle par exemple en l installant dans un cadre fermé à clé 2 Pour la section et le type des câbles la RIB conseille d utiliser un câble de type H05RN F ayant u...

Page 3: ...gnetisch mit minimaler Öffnung der Kontakte bzw 3mm welcher die Übereinstimmungszeichen der internationalen Normen aufweist Diese Vorrichtung muss geschützt werden vor einer ungewollten Schließung z B wenn sie in einer abgeschlossenen Schalttafel installiert ist 2 Für die Sektion und für den Kabel Typ empfiehlt RIB die Benutzung eines Kabels des Typs H05RN F mit Minimalsektion von 1 5 mm2 und auf ...

Page 4: ...y portales motorizados atenerse a las normas y a las leyes vigentes 2 El instalador tendrá que dar al utilizador final un manual de instrucciones de acuerdo con la EN 12635 3 El instalador antes de proceder con la instalación tiene que hacer una analisis de los riesgos del cierre automatizado final y la puesta en seguridad de los puntos identificados como peligrosos siguiendo las normas EN 12453 E...

Page 5: ...omando incorporato Sono da collegare solamente i fili di una pulsantiera e naturalmente della tensione di alimentazione Per i collegamenti ed i dati tecnici degli accessori attenersi ai relativi libretti di istruzione Barriera PRESIDENT Fotocellule Colonnina porta fotocellula Sensore magnetico Selettore a chiave Antenna radio CARATTERISTICHE TECNICHE PRESIDENT Lunghezza max asta m 3 4 Tempo di ape...

Page 6: ...lle4m pdf ASSEMBLAGGIO ASTA NEL MOZZO PORTA ASTA Infilate l asta dalla parte col diametro maggiore nel mozzo Fig 23 ATTENZIONE Ruotate l asta nel mozzo in modo che le viti siano perpendicolari alla piastra del mozzo Fig 24 Bloccate l asta nel mozzo strigendo le due viti con una chiave a brugola n 5 Fig 25 INSERIMENTO MOZZO CON ASTA SU OPERATORE Montate il mozzo con l asta in posizione verticale su...

Page 7: ...orporato in funzione di rilevatore di presenza A COLLEGAMENTI ELETTRICI PARK 24V cod BC07061 B SW1 MICROINTERRUTTORI PER IL SETTAGGIO DEL QUADRO ELETTRONICO DIP 1 TARATURA RALLENTAMENTO DEL MOTORE ON PUNTO C DIP 2 PROGRAMMAZIONE TEMPI ON PUNTO D MICROINTERRUTTORI DI GESTIONE DIP 3 Tempo di attesa prima della chiusura automatica ON max 5 min DIP 4 Ricevitore radio passo passo OFF automatico ON DIP ...

Page 8: ...meccanico di apertura l ENCODER ferma il motore con memorizzazione delle letture dell encoder e del tempo e si attiva il conteggio del tempo d attesa prima della chiusura automatica max 5 minuti 5 Premete il pulsante PROG Si ferma il conteggio del tempo d attesa prima della chiusura automatica e la sbarra chiude Nello stesso istante il led DL5 smette di lampeggiare segnalando l uscita dalla proced...

Page 9: ...l apertura la sbarra apre durante l apertura le fotocellule non interverranno Le fotocellule interverranno solo in fase di chiusura con ripristino del moto inverso dopo un secondo anche se le stesse restano impegnate N B Si raccomanda di verificare la funzionalità delle fotocellule almeno ogni 6 mesi ATTENZIONE Se il led del ricevitore rimane acceso è possibile che siano presenti dei disturbi sull...

Page 10: ...CCESO SPENTO PRESIDENT APERTA ACCESO SPENTO SPENTO ACCESO PRESIDENT IN CHIUSURA ACCESO SPENTO ACCESO SPENTO MODO DI FUNZIONAMENTO PARK DIP 6 ON CON EXPANDER CARD SCHEMA D DRAWING D PER ENTRARE A condizione che un autovettura sia presente sul sensore magnetico può essere comandata l apertura della sbarra tramite pulsante APERTURA 1 passo passo o comando radio La sbarra rimarrà aperta fin quando l a...

Page 11: ...matica Alla chiusura del cancello si spegne la luce verde e si accende la luce rossa A fine chiusura il semaforo è spento SCHEDA DI CARICA BATTERIA Il tempo di ricarica completa delle batterie da 12Vdc 1 2Ah n 2 pezzi collegati in serie opzionale cod ACG9511 alla prima installazione é di 24 ore con una corrente di carica di 0 03A ALIMENTAZIONE SPIA DI SEGNALAZIONE STATO BATTERIA MORSETTI 3 11 In c...

Page 12: ...ata cod ACG7061 SUPPORTO LATERALE cod ACG7042 ANTENNA SPARK 433 cod ACG5452 SPIRA LOOP PREASSEMBLATA 6 m perimetro 2 x 1 15 m di cavo cod ACG9067 10 m perimetro 3 x 2 15 m di cavo cod ACG9068 FOTOCELLULE NOVA Wireless Segnalazione batteria scarica portata 30 m durata batterie oltre 3 anni cod ACG8047 BATTERIE ALCALINE 4 x 1 5V cod ACG9519 SUN 2CH cod ACG6052 SUN 4CH cod ACG6054 SUN CLONE 2CH cod A...

Page 13: ... au coffret électrique de commande incorporé Il faut seulement brancher les fils d un bouton poussoir et naturellement de la tension d alimentation Pour les branchements et les données techniques des accessoires se conformer aux livrets d instruction correspondants Barrière PRESIDENT Photocellules Colonne porte photocellule Détecteur magnétique Sélecteur à clef Antenne radio CARACTÉRISTIQUES TECHN...

Page 14: ... moyeu de façon à ce que les vis soient perpendiculaires à la plaque du moyeu Fig 24 Bloquer la lisse dans le moyeu en serrant les deux vis avec une clé Allen n 5 Fig 25 INSERTION DU MOYEU AVEC LISSE SUR OPERATEUR Monter le moyeu avec la lisse en position verticale sur l arbre de l opérateur et le bloquer en serrant les deux vis fournies avec une clé Allen n 6 Fig 26 27 BRANCHEMENTS ELECTRIQUES Ou...

Page 15: ...ENTRALE DIP 1 ETALONNAGE RALLENTISSEMENT DU MOTEUR ON POINT C DIP 2 PROGRAMMATION TEMPS ON POINT D MICRO INTERRUPTEURS DE GESTION DIP 3 Temps d attente avant la fermeture automatique ON max 5 min DIP 4 Récepteur radio pas à pas OFF inversion ON DIP 5 Commande impulsion unique K BUTT pas à pas OFF inversion ON DIP 6 Fonctionnement normal OFF Fontionnement Park ON DIP 7 Exclusion encodeur comme sécu...

Page 16: ...einte l ENCODEUR arrête le moteur avec mémorisation des lectures de l encodeur et du temps et le compte du temps d attente est mis en action avant la fermeture automatique max 5 minutes 5 Appuyer sur le bouton PROG Le compte du temps d attente avant la fermeture automatique s arrête et la barrière se ferme Au même instant la led DL5 arrête de clignoter en signalant la sortie de la procédure d appr...

Page 17: ...n de commande PHOTOCELLULE bornes 3 4 Quand la barrière est baissée si un obstacle est interposé au rayon des photocellules et si l ouverture de la barrière est commandée la barrière s ouvre durant l ouverture les photocellules n interviennent pas Les photocellules interviennent seulement en phase de fermeture avec relance du mouvement inverse après une seconde même si celles ci sont toujours en a...

Page 18: ... ET IN PARK NE SONT PAS ACTIVES ALORS QUE LA GESTION DES FEUX ET LA LUMIERE DE SERVICE SONT DISPONIBLES GESTION FEUX EN FONCTIONNEMENT NORMAL AVEC EXPANDER SCHEMA B SORTIE 1 NO SORTIE 2 NO ROUGE IN VERT IN PRESIDENT FERME ETEINT ETEINT PRESIDENT OUVRE AVEC OUVER 1 ALLUME ETEINT PRESIDENT OUVERT ETEINT ALLUME PRESIDENT EN FERMETURE ALLUME ETEINT SCHEDA D SORTIE1 NC SORTIE1 NO SORTIE2 NC SORTIE 2 NO...

Page 19: ...ARGEUR BATTERIES Le temps de la recharge complète des batteries de 12Vdc 1 2Ah n 2 batteries branchées en série option code ACG9511 à la première installation est de 24 heures avec un courant de charge de 0 03A ALIMENTATION VOYANT DE SIGNALISATION ETAT BATTERIE BORNES 3 11 En cas de manque de courant et d intervention de la batterie d urgence ce voyant s allume en signalant le manque de courant et...

Page 20: ...térieure en cuivre dans le cas contraire le fonctionnement de l antenne serait nul L antenne doit être installée de façon perpendiculaire et être en vue de la télécommande FEU CLIGNOTANT SPARK avec carte intermittente incorporée code ACG7061 SUPPORT LATERAL code ACG7042 ANTENNE SPARK 433 code ACG5452 PHOTOCELLULES NOVA Wireless Signalisation batterie déchargée portée 30 m durée batteries de plus d...

Page 21: ...ctronic board You just need to connect the wires of a keyboard and of course of the feeding tension For the connections and the technical data of the fixtures follow the relevant handbooks TECHNICAL DATA PRESIDENT Max boom lenght m 3 4 Opening time s 3 3 5 Power supply 230V 50 60Hz Capacity W 74 Power absorbed A 0 32 Power supply 120V 60Hz Capacity W 72 Power absorbed A 0 6 Max torque Nm 100 130 N...

Page 22: ... the hub with the rod on the shaft of the operator and fix it by tightening the two screws supplied with a socket head screw no 6 Fig 26 27 ELECTRIC CONNECTIONS Open the side panel with a socket head screw no 4 to have access to the electronic board Fig 28 29 30 31 32 Insert your hand inside the operator to pull out the electric cables you had formerly leaned on the operator support plate Carry ou...

Page 23: ...G TIMES ON OPERATING MICROSWITCH DIP 3 Waiting time before the automatic closing ON max 5 min DIP 4 Step by step radio receiver OFF automatic ON DIP 5 Single impulse control K BUTT step by step OFF automatic ON DIP 6 Normal working OFF Park working ON DIP 7 Encoder exclusion as security OFF encoder on ON encoder off DIP 8 Function of the key OPENING 2 check in Park mode ON the key OPENING 2 is alw...

Page 24: ... lightening thus signalling the exit from the machine learning procedure From this moment the securities or other controls of the gate will normally work reversals stop alarms etc 6 The closing of the bar will be carried out in speed mode and in the proximity of the total closing in slow down mode 7 Once the ENCODER calculation is over the bar stops AT THE END OF THE PROGRAMMING PUT THE DIP 2 BACK...

Page 25: ...ing phase with reset of the reverse motion after a second even if they are busy N B Every six months make sure to check that photocells are not out of order ATTENTION In case the receiver led remains lit malfunctioning of the main supply is suspected It is advisable to connect electrically the photocells stands to the contact 10 to shield the photocells from external noise Be careful not to short ...

Page 26: ...TROLS OF THE EXPANDER BOARD THUS KEEP ATTENTION IF DIP 6 OFF NORMAL FUNCTIONING THE OPENING CONTROLS 2 OK CLOSE AND IN PARK ARE NOT ACTIVE WHILE THE MANAGEMENT TRAFFIC SIGNAL AND THE COURTESY LIGHT ARE AVAILABLE MANAGEMENT TRAFFIC SIGNAL WITH NORMAL FUNCTIONING WITH EXPANDER DRAWING B EXIT 1 NO EXIT 2 NO RED IN GREEN IN PRESIDENT CLOSE OFF OFF PRESIDENT OPENS WITH OPENING 1 ON OFF PRESIDENT OPEN O...

Page 27: ...ches off and the red light switches on When the closing is completed the traffic signal is OFF BATTERY CHARGE CARD The time for the complete recharge of 12Vdc 1 2Ah batteries n 2 pieces connected in series optional cod ACG9511 at the first installation is of 24 hours with a charge current of 0 03A BATTERY STATE SIGNALLING PILOT LIGHT FEEDIN TERMINALS 3 11 In case the network tension lacks and the ...

Page 28: ...of the cable to came Into contact with the external copper sheath since this would prevent the antenna from working Install the antenna vertically and in such a way the remote control can reach it SPARK BLINKER WITH IN BUILT INTERMITTENT CARD code ACG7061 LATERAL SUPPORT code ACG7042 SPARK ANTENNA 433 code ACG5452 PHOTOCELLS NOVA Wireless empty batteries warning range 30 m more than 3 years batter...

Page 29: ...s der elektrischen eingegliederten Steuerschalttafel angeschlossen Es müssen nur die Drähte einer Schalttafel und natürlich die Stromspannung angeschlossen werden Für die Anschlüsse und die technischen Daten der Zubehöre verweisen wir auf die entsprechenden Betriebsanleitungen D Schranke PRESIDENT Fotozellen Säulenträger für Fotozelle Magnet Sensor Schlüsselschalter Radio Antenne TECHNISCHE EIGENS...

Page 30: ...laden werden www ribind it pdffiles regmolle4m pdf MONTAGE DER SCHRANKE AUF DIE NABE Die Schranke wird nun mit dem größeren Durchmesser auf die Nabe gesetzt Abb 23 ACHTUNG drehen der Schranke auf der Nabe bis die Schrauben senkrecht zur Platte der Nabe stehen Abb 24 Die Schranke in der Nabe muss nun durch das Anziehen der zwei Schrauben mit einem Inbusschlüssel Nr 5 festgezogen werden Abb 25 MONTA...

Page 31: ...Encoder fungiert als Einrichtung zur Einschränkung der auswirkenden Kräfte nach Norm EN12453 Anhang A D Eingebauter Encoder als Hindernis Melder A ELEKTROANSCHLÜSSE PARK 24V Kode BC07061 B SW1 DIP SCHALTER FÜR DAS EINSTELLEN DER STEUERUNG DIP 1 KONTROLLE DREHRICHTUNG MOTOR ON PUNKT C DIP 2 ZEIT PROGRAMMIERUNG ON PUNKT D DIPSCHALTER BETRIEB DIP 3 Wartezeit vor automatischer Schließung ON max 5 min ...

Page 32: ... stoppt den Motor mit Speicherung der Encoder Lesungen und der Zeit Die Zählung der Wartezeit vor der automatischen Schließung max 5 Min aktiviert sich 5 Taste PROG drücken Die Zählung der Wartezeit vor der automatischen Schließung stoppt und die Schranke schließt sich Gleichzeitig hört Led DL5 auf zu blinken und zeigt den Ausgang der Laufprozedur an Von diesem Zeitpunkt an funktionieren die Siche...

Page 33: ... 5 Minuten zu signalisieren und der Blinker wird während einer Minute aktiv sein Während oder nach 5 Minuten akustischen Alarms Buzzer Optional ist es möglich die Schrankenfunktion wieder herzustellen indem man eine beliebige Steuerungstaste betätigt FOTOZELLEN Klemmen 3 4 Bei gesenkter Schranke wenn ein Hindernis vor den Fotozellen steht und die Öffnung befohlen wird öffnet sich die Schranke währ...

Page 34: ...GEN DER EXPANDER KARTE FREI UND BLOCKIERT ANDERE DEMZUFOLGE BEACHTEN WENN DIP 6 OFF FUNKTION NORMAL DIE ÖFFNUNGSTEUERUNGEN 2 OK CLOSE UND IN PARK SIND NICHT AKTIV WÄHREND DER BETRIEB DER AMPEL UND DES FUNKTIONSLICHTES VORHANDEN SIND AMPELBETRIEB MIT NORMALFUNKTION MIT EXPANDER ZEICHNUNG B AUSGANG 1 NO AUSGANG 2 NO ROT IN GRÜN IN PRESIDENT GESCHLOSSEN AUS AUS PRESIDENT ÖFFNET MIT ÖFFNUNG 1 EIN AUS ...

Page 35: ...ht bleibt eingeschaltet bis die automatische Schließung beginnt Bei Schließung des Tores schaltet das grüne Licht aus und das rote Licht schaltet ein Bei totaler Schließung ist die Ampel ausgeschaltet BATTERIE LADEKARTE Die vollständige 12Vdc 1 2Ah Batterie Ladezeit 2 Stücke in Serie angeschlossen optional Kode ACG9511 beträgt bei der ersten Installation 24 Stunden mit einer Stromladung von 0 03A ...

Page 36: ...ng nicht mit der externen Kupferumwicklung in Kontakt kommt da dies die Funktion der Antenne außer Kraft setzt Die Antenne muss senkrecht von dem Fernbetätigungsgerät aus sichtbar montiert werden BLINKER SPARK mit eingebauter wechselsignalkarte Kode ACG7061 SEITENLAGER Kode ACG7042 ANTENNE SPARK 433 Kode ACG5452 NOVA WIRELESS FOTOZELLEN Meldung erschöpfter Batterie Reichweite 30 Meters Batterienle...

Page 37: ...RESIDENT el motor y el encoder ya están conectados al panel eléctronico de mando incorporado Se pueden conectar los hilos de un tablero de bornes y naturalmente de la tensión de alimentación Barrera PRESIDENT Fotocélulas Columna porta fotocélula Sensor magnético Selector a llave Antena de radio CARACTERISTICAS TECNICAS PRESIDENT Longitud máxima de la asta m 3 4 Tiempo de apertura s 3 3 5 Alimentac...

Page 38: ...en el buje Fig 23 CUIDADO Girar la barra en el buje en modo de que los tornillos queden perpendiculares a la plancha del buje Fig 24 Bloquear la barra en el buje apretando los dos tornillos con una llave Allen n 5 Fig 25 INTRODUCCIÓN DEL BUJE CON LA BARRA EN EL OPERADOR Montar el buje en posición vertical en el árbol del operador y bloquearlo apretando los dos tornillos en dotación con una llave A...

Page 39: ...AS PARK 24V còd BC07061 B SW1 MICROINTERRUPTOR PARA LA CONFIGURARACIÓN DE LA CENTRAL DIP 1 CONTROL DEL SENTIDO DE ROTACIÓN DEL MOTOR ON PUNTO C DIP 2 PROGRAMACIÓN DE LOS TIEMPOS ON PUNTO D MICROINTERRUPTORES PARA PROGRAMAR LA CENTRAL DIP 3 Tiempo de espera antes del cierre automático ON máx 5 mín DIP 4 Receptor de radio paso paso OFF automático ON DIP 5 Mando con impulso único K BUTT paso paso OFF...

Page 40: ...carrera 2 Poner el microinterruptor DIP 2 en ON El led DL5 hará breves parpadeos 3 Presionar el pulsador PROG la barra se abre 4 Al alcanzar el bloqueo mecánico de abertura el ENCODER para el motor con memorización de las lecturas del encoder y del tiempo y se activa el conteo del tiempo de espera antes del cierre automático máx 5 minuti 5 Presionar el pulsador PROG Se para el conteo del tiempo de...

Page 41: ...nes 3 4 Con barra bajada si un obstáculo se interpone a los rayos de la fotocélulas y se comanda la abertura la barra abre durante la abertura las fotocélulas no intervendrán Las fotocélulas intervendrán solo en fase de cierre con reiniciación del movimieto inverso después de un segundo aunque si quedan ocupadas NB se recomienda verificar cada 6 meses la funcionalidad de las fotocélulas ATTENCION ...

Page 42: ...A 1 NO SALIDA 2 NO ROJO IN VERDE IN PRESIDENT CERRADA APAGADO APAGADO PRESIDENT ABRE CON ABERTURA 1 ACCESO APAGADO PRESIDENT ABIERTA APAGADO ACCESO PRESIDENT EN CIERRE ACCESO APAGADO TARJETA D SALIDA1 NC SALIDA1 NO SALIDA 2 NC SALIDA 2 NO ROJO IN VERDE IN ROJO OUT VERDE OUT PRESIDENT CERRADA ACCESO APAGADO ACCESO APAGADO PRES ABRE CON ABERTURA 1 ACCESO APAGADO ACCESO APAGADO PRESIDENT ABIERTA APAG...

Page 43: ...áforo está APAGADO TARJETA DE CARGA DE LA BATERÍA El tiempo de carga completa de las baterías de 12Vdc 1 2Ah n 2 piezas conectadas en serie opcional cód ACG9511 para la primera instalación y de 24 horas con una corriente de carga de 0 03A ALIMENTACIÓN DE LA LUZ DE TESTIGO DE INDICACIÓN DEL ESTADO DE LA BATERÍA BORNES 3 11 En el caso de que no haya tensión en la red y se encienda la batería de emer...

Page 44: ...n contacto con la protección de cobre externa Esto impediría el funcionamiento de la antena Instale la antena verticalmente y de tal manera el mando a distancia puede alcanzarla INTERMITENTE SPARK con tarjeta intermitente incorporada cód ACG7061 SOPORTE LATERAL cód ACG7042 ANTENA SPARK 433 cód ACG5452 FOTOCELULAS NOVA WIRELESS indicador de baterías descargadas alcanze 30 m duración baterías 3 años...

Page 45: ...45 NOTES ...

Page 46: ...ecorsa sic CEL1475 Cavetto terra CEL1520 Supp a sella x fascette 5499 CEL1522 Morsettiera portaf OK133 2 CEL1533 Trasf tor 130VA P230 S18 CME2140 Perno per cerniera CME2142 Corona elicoidale CME2143 Innesto Sblocco CME2144 Perno sblocco CME2145 Inserto filettato CME2146 Vite senza fine CME2147 Bussola Piastra Base CME2148 Tirante Colonna CME2149 Pattino antiusura per molle CME2171 Albero traino br...

Page 47: ...pp a sella x fascette 5499 CEL1522 Morsettiera portaf OK133 2 CEL1533 Trasf tor 130VA P230 S18 CME2140 Perno per cerniera CME2142 Corona elicoidale CME2143 Innesto Sblocco CME2144 Perno sblocco CME2145 Inserto filettato CME2146 Vite senza fine CME2147 Bussola Piastra Base CME2148 Tirante Colonna CME2149 Pattino antiusura per molle CME2158 Guscio centrale CME2171 Albero traino brocciato CME2172 Moz...

Page 48: ...roduct can not work alone and was designed to be fitted into a system made up of various other elements Hence it falls within Article 6 Paragraph 2 of the EC Directive 2006 42 Machines and following modifications to which respect we point out the ban on its putting into service before being found compliant with what is provided by the Directive Dieses Produkt kann nicht allein funktionieren und wu...

Reviews: