SIMPLIFIED INSTRUCTIONS FOR SUPER 8000 FAST WITH L1-CRX
1° Connecting the motor and limit switch (done in the factory)
ITA ESP ENG FRA GRE DEU RUS ARA THAI BUL FAR TUR HIN CHI
BLINKER
230Vac 40W MAX
COMMON
PHOTOCELL 1
PEDESTRIAN
OPEN
STOP
CLOSE
TIMER
SINGLE COMMAND
LED
R=2,2K 1/4W
COMMON
COMMON
COMMON
EDGE 2
PHOTOCELL 2
EDGE 1
A+TEST / A-
PHOTOCELLS
AUTO-TEST
ANTENNA
433 MHz
ANTENNA
BRAIDING
24Vdc 0,4A ±15%
24Vdc 0,4A ±15%
TCA TRIMMER - AUTOMATIC CLOSING pause time regulator for TOTAL or PEDESTRIAN openings
default NOT ACTIVATED and LED DL11 OFF (trimmer fully rotated counterclockwise)
This trimmer makes it possible to adjust the pause time for total or pedestrian automatic closing. Only with gate completely open (total) or partially open (pedestrian) and LED DL11 ON (trimmer
rotated clockwise to activate the feauture).
The pause time (for a totally opened gate) can be adjusted from a minimum of 2 s up to a maximum of 2 minutes.
The pause time (for gate open with PED. control) can be adjusted from a minimum of 2 seconds to a maximum of 30 seconds.
2 – LIMIT SWITCH ADJUSTMENT
SUPER 8000 FAST has 4 independent watertight limit switches mounted on the motor-reducer,
that are set to command the start of the deceleration and the stop of the movement of the
gate in both directions.
Fix the decelaration cams CCA1643 and CCA1644 as shown in the drawing.
CCA1642
≥90cm
≥90cm
CCA1644
CCA1643
CCA1642
EMERGENCY RELEASE
To be able to open the gate manually, open the cover with the appropriate key and turn handle
“A” in an anti-clockwise direction.
To restore the electric functioning operate in the opposite direction.
Install a
Residual Current Circuit
Breaker like
ABB F204A-25/0,3