6
SPEED
Press SPEED key to select three counting levels: SP-L means lower counting speed,
SP-M means medium counting speed(default),SP-H means high counting speed
RESET
In NORM counting mode, press RESET key
。
to show the quantity of counted notes.
In VALUE counting mode, press RESET key to show the denomination, amount and
accumulation amount of the counted notes.
Keep pressing RESET key for 3 seconds, the machine will default back to the factory
setting
, it will show DEFAULT…
CLEAR
Press this key to clear the error code
、
counting number
、
accumulation number
、
batch number
。
START
Press this key to clear the error code and continue counting when an error occurs. In
manual counting mode, press START key to start the machine.
LCD DISPLAY
to display the status under each mode.(matrix 128*64)
Precautions
Before connecting your currency counter
with the local domestic mains supply, please
ENSURE that your local mains voltage is
correctly shown by the Switch, either ‟110‟
or ‟220‟ volts, mounted on the rear of the
machine. If the indication is incorrect,
ensure the machine is disconnected with
the electrical source. Then the Switch can
be easily moved to the correct position
using a suitable blunt implement.
DO NOT drop any clothing, hair, paper clips, staples, etc., into the Hopper area. If the
Optical Sensor is obscured, the Document Feeding System will operate without
warning.
Before you turn on the machine, please ensure you remove ALL Notes from the
Hopper and Stacker areas.
OPERATION
To make the best use of the machine, please operate in the following procedures.
Start
Turn on the Power Switch on the rear of the machine. The machine will enter into a
'Self-
Test' mode. The display will show “BC2000-US” and the Motor systems will run for
approximately 1 second, then, if correct, the Motors will stop and the display will change to