background image

Operation Instructions V1.0 

PF-9007 Multi-Currency & Documents Detector

 

 

  3   

The LED indicator on right side from the top down: top white light, side white 
light,  bottom  white  light,  top  IR  940nm(reserved),  top  IR  850nm,  side  IR, 
bottom IR, UV. 
 

Key Function 

 

DL

  key:  For  changing  the  white  light,  Top  white  light,  Side  white  light  and 

Bottom  white  light  mode;  When  you  are  using  white  light  mode,  other  light 
source is turned off.   
Top white light: For detecting the banknotes quality, color and latent image. 
Side white light: For detecting the intaglio printing mark and OVI figure; 

Bottom  white  light:  For  detecting  the  watermark,  metal  thread  and 

“Micro 

Perforation

” Mark; 

UV 

key: For turning the UV (ultraviolet) light on or off; When you are using UV 

mode, other light source is turned off. 
UV light is for detecting the fluorescent printing and fibers; 

IR

 key: For changing top infrared light mode,side infrared light mode, bottom 

infrared light modeor blink mode; 
IR light is for detecting the infrared ink image under 7inch LCD screen. 
Blink mode is the mode that two infrared lights turn on alternately for checking 
if there are the 

„M‟ elements on banknote; 

Blink mode is the alternate blinking of top infrared light and bottom infrared 
light for checking the blinking features.   

MODE

 key: If the display is not under parameter adjusting mode, press MODE 

key to select the whole image detecting mode, partial image detecting mode 
and MAG video agjusting mode.   

Keep pressing MODE key, you will enter into parameter adjusting mode. 

Under this mode, press MODE, you can adjust Brightness, Contrast of the 
LCD display, color and the mirror image menu.(Under parameter adjusting 
mode, if you do not press MODE key or “+”,”-” key, the machine will exit from 
adjusting mode.   

“+”

 key : Under normal detecting mode, press this key to select top infrared 

light&UV, top infrared light&bottom infrared light, top white light, side white light, 
bottom white light, top infrared light, side infrared light, bottom infrared light 
and UV detecting mode.   

Under parameter adjusting mode, this key can increase the parameter value of 

current menu. 

“-”

 key: Under normal detecting mode, press this key to select various light 

mode oppositely as + key.   