Getting started:
The RibbonJoG
®
mkII Cable Tester will require fitting of batteries ( not supplied).
Using a No 0 'Supadrive screwdriver remove the countersunk screw on the base
plate to gain access to the battery compartment. Fit four AAA size alkaline or zinc
chloride batteries with polarisation as indicated on the circuit board.
Batteries / Power Saving:
Under normal use the batteries should give at least a years use. However, to
preserve battery life RibbonJoG
®
mkII has a 'Power Saving' feature. After 15
minutes of inactivity RibbonJoG
®
mkII will put the microprocessors into sleep
mode. Switch OFF and then ON again to reset RibbonJoG
®
mkII. Cable details
held in memory will not be lost.
Test Procedure
There are 10 Identifier Light Emitting Diodes (LED's) on the left (red) side of the
unit, each is connected to the last pin of the connector below it. Checking the
status of the ribbon cable is made using the TEST button.
1
. Plug one end of the cable to be tested into an appropriate socket using the
right hand (Blue) half of the RibbonJoG
®
mkII.
2
. Plug the other end of the cable to be tested into an appropriate socket using
the left hand (Red) half of the RibbonJoG
®
mkII.
3
. Switch ON.
If no cable has been plugged in each of the LEDS will light in turn. After this the
tester is ready. Should the MEMORY option have been used then the MEMORY
LED will stay ON to indicate that the comparison test will be carried out against
stored cable details. If this is not the case then please check and replace the
batteries if required , otherwise return the RibbonJoG
®
mkII for repair.
4
. To start the test press and release the TEST button.
5. Standard test (memory option not used)
Each wire is tested separately, as the wire corresponding to a identifier LED is
tested the LED will light. The test stops at the first wire with no connection
between the left and right hand connectors.
6. Standard test, results
a) PASS
The Pass LED will be on as well as one of the connector identifier
LED's. This shows the last good connection found, not necessarily the size of
connector used. The Pass LED will only come on if the number of connections
found corresponds to one of the 10 possible connector sizes (see page I).
6. Standard test, results
b) FAIL - OPEN circuit
The Fail OPEN LED will be on as well as one
of the connector identifier LED's. This shows the last good connection found,
so the fault occurred somewhere between the last pin of the connector
identified and the last pin of the next connector.
c) FAIL - SHORT circuit
The Fail SHORT LED will be on, as well
two connector identifier LED's showing that the short circuit is locate between
them. If only the No. 10 identifier LED will be lit and the short is somewhere in
the first 10 pins.
7
. A non-standard cable assembly will fail the standard test. RibbonJoG
®
mkII
can test non-standard cables by identifying and storing all the connections in
that cable. These stored details can then be used to test against other cables.
Connect the non-standard cableand press the TEST button. On completion of
the standard test press and hold the test button until the MEMORY LED come's
on. Releasing the test button will cause RibbonJoG
®
to go through the test
again, this time not stopping until the last pin (64). The connection details will
be put into memory. After all 64 pins have been stored RibbonJoG
®
will be
ready.
8. Memory Test
The MEMORY will stay on during the test.The test stops at the last wire (64).
The memory can hold up to 128 differences from the normal pin 1 to pin 1, pin
2 to pin 2 etc. connections.
9. Memory Test Results
a) PASS
- The Pass LED will turn on.
b) FAIL
- OPEN circuit
, the Fail OPEN LED will be on.
c) FAIL
- SHORT circuit,
the Fail SHORT LED will be on.
As in the standard test (section 6) the PASS and FAIL LED's work in
conjunction with the identifier LED's to give as much information as possible
about the cable under test. However because the connection details in memory
may be very complicated the identifier LED's may not be able show the true
fault location.
10
. On completion of the test it is possible to reset the MEMORY option by
pressing and holding the test button until the MEMORY LED goes of f .
Releasing the test button will cause the RibbonJoG
®
mkII to go through the
standard test