II�FullSizeCanisterTroubleshootingGuide
07�03�07
10
E. Power Nozzle Cuts On and Off When Using - Troubleshooting Wand
NOTE:Ifwarninglightisred,therearenoheadlights,andpowernozzlewon’trun,presstheresetbutton�
E�
Step 1.
1�TurnthepowernozzleON�
2�Holdingthehosehandlewithonehand,twistthewandwiththeotherhand�
3�Ifthenozzledoesnotcutoff
continue to Step 2
�
4�Ifthenozzlecutsofftheproblemisintheconnectionatthehosehandle�
5�Replaceconnectorsorhoseandre-testthepowernozzle�
E�
Step 2.
1�Holdingthewandwithonehand,twistthenozzlewiththeotherhand�
2�Ifthenozzledoesnotcutoff
continue to Step 3
�
3�Ifthenozzlecutsoff,theproblemisintheconnectionatthelowerendofthewandorthecanisterconnectionplug�
4�Changethewandandre-test�Ifgoodchangethecanisterconnectionplug�
5�Re-assembleandre-test�
E�
Step 3.
1�Holdingthewandwithonehand,holdthenozzledownandpullonthewandwiththeotherhand�
2�Ifthenozzlecutsoff:
a�Checktheneckonthepowernozzletoseeifitiscrackedoroneoftheprongsinthecanisterconnectionplugispulled
looseorbroken�
b�Checkforwearonthecatchintheneckassembly�
c�Ifneckiscrackedorthecatchiswornchangetheneckassembly�
d�Iftheprongsarebroken,bent,orshort(lessthan10mm)replacethenozzlepowercord�
3�IfthenozzledoesNOTcutoff:
a�Checktheplayinthewandtoneckassembly�Ifthereistoomuchplay,nozzlewillcutout�
b�Tryanotherwandandre-testand/orchangeouttheneck�
Figure B. Power Nozzle Reset Switch Location
Circuit Breaker Switch