background image

150-10-5

Digital Physician Scale

Software Version 11525

Operation Manual

PN 126150 Rev G

August 18, 2022

Summary of Contents for 150-10-5

Page 1: ...150 10 5 Digital Physician Scale Software Version 11525 Operation Manual PN 126150 Rev G August 18 2022 ...

Page 2: ... respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserves the right to make changes to the technology features specifications and design of the equipment without notice The most current version of this publication software firmware and all other product updates can be ...

Page 3: ...ning or obtained by calling 715 234 9171 and asking for the training department Revision History This section tracks and describes the current and previous manual revisions for awareness of major updates and when the updates took place Revision Date Description G August 18 2022 Established a revision history formatted content to match other medical manuals software version 11525 Table i Revision L...

Page 4: ...embly 3 2 1 Unpacking 3 2 1 1 Repacking Scale 3 2 2 Scale Assembly 3 2 3 Height Rod Installation 5 2 4 Inserting Batteries 5 2 5 AC Power Connections 6 2 6 Leveling the Scale 6 3 0 Operation 7 3 1 Weighing 8 3 2 Hold Release Function 8 3 3 Using the Body Mass Index BMI Function 8 3 4 Troubleshooting 9 3 5 Using the Height Rod 10 4 0 Communication 12 4 1 Push button Keypad Print 12 4 2 USB Connecti...

Page 5: ... equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interfer...

Page 6: ...rt the scale while someone is on the scale Do not allow minors children or inexperienced persons to operate this scale Do not use in the presence of flammable materials Do not use this product if any of the components are loose or cracked Do not use near water Do not use the scale on slippery surfaces such as a wet floor Do not use this scale when a person s body or feet are wet such as after taki...

Page 7: ...2 Wheel hinge 1 Pan head screws 8 AA batteries 6 2 1 1 Repacking Scale All component parts have been wrapped in plastic Retain the packaging for use in the event that the scale must be returned or moved It must be properly packed with sufficient packing materials Whenever possible use the original shipping carton when shipping the scale back Damage caused by improper packaging is not covered by th...

Page 8: ...ecurely Figure 2 3 Attach Wheel Assembly 7 Ensure that the cable is extending through the top of the lower column 8 Plug the cable from the lower column into the upper column Figure 2 4 Extend Cable Through Scale Column 9 Place the upper column onto the lower column aligning the screw holes Ensure the cable does not get pinched Figure 2 5 Insert Upper Column into Lower Column 10 Secure with two sc...

Page 9: ...eight rod pieces together Figure 2 6 Back of Height Rod 2 Slide the assembled height rod from the top of the column into the slot located on the front of the scale Figure 2 7 Height Rod Assembly 2 4 Inserting Batteries The six AA batteries that come with the scale offer an average of 25 hours of continuous use To install the batteries 1 Open the battery chamber cover by loosening the thumb screw 2...

Page 10: ...below Rice Lake Weighing Systems offers optional AC adapters utilizing an adapter not supplied by Rice Lake Weighing Systems voids all warranties Figure 2 9 Power Connection 2 6 Leveling the Scale Use bubble level to check for level and adjust feet as needed On a flat surface adjust the scale feet until the bubble indicates that the scale is level Figure 2 10 Bubble Indicates Scale Is Level Connec...

Page 11: ...off the scale A second press releases the weight value Not active while in BMI mode BMI Pressing the BMI key enables access to the BMI Body Mass Index mode defaults when scale is turned on The patient is gets on the scale weight stabilizes and press the BMI key The display then asks for the patient height to calculate out the patient BMI CLEAR When using the BMI function the display will be lookin...

Page 12: ...e to zero Pressing prior to the patient getting on the scale will also hold the weight display 3 3 Using the Body Mass Index BMI Function Use the following steps in determining the BMI LB Mode 1 Ensure the scale is at zero 2 Have the patient step onto the scale 3 Have the person step on the scale to obtain a weight The LOCK annunciator appears on the display 4 Press The BMI and FT IN annunciators ...

Page 13: ...ale E4L BAT Battery low but still usable one bar left on indicator display E4U Battery low and unstable no bars left on indicator display E11 CAL Calibration Error recalibrate scale Err 1 Load cell cable may be plugged into wrong connection port Ensure cable is connected to the load cell connection port Note Load cell connection point is located underneath the curved plastic cover of the indicator...

Page 14: ...ite latch located next to the indicator display and pull it up vertically Figure 3 2 Pull up on White Latch to Extend Height Rod 2 Raise the headpiece until it is perpendicular to the height rod and snaps into place Figure 3 2 3 Raise the rod until the patient can easily stand without touching the headpiece 4 Have the patient step onto the scale with their head level 5 With a patient on the scale ...

Page 15: ... taller than 43 in 109 cm use the measurements at the read line inner rod Figure 3 4 Read Line Location For patients shorter than 43 in 109 cm use the outer sleeve measurements below the read line Figure 3 5 Read Measurement for Patients Under 43 in 109 cm Read Line Read Line ...

Page 16: ...ess and hold for at least three seconds or until the scale emits two quick beeps If the scale does not beep after five seconds release as the weight was either in motion or out of range If displaying weight and not BMI the scale will send out the following 21 character string xxxxxxxxx SP uu SP mmmmm SP CR LF Table 4 1 Print Format Tokens Example 10 Lb net SP SP SP SP 10 0 SP lb SP SP Net SP SP SP...

Page 17: ... the use of the USB driver Driver protections may need to be temporarily disabled on Windows 10 or later computers to allow for the installation of the USB driver 1 Connect the scale s indicator to a PC using a USB Type B to USB Type A cable not included 2 Turn the indicator on In most cases the PC should find the driver and automatically configure the driver when the scale is plugged into a USB p...

Page 18: ...e personnel Go through the following steps for basic maintenance Check the overall appearance of the entire scale for any obvious signs of damage Inspect the condition of the AC power adapter cord for cracking fraying or for broken or bent prongs 5 2 Cleaning Proper care and cleaning is essential to ensure a long life of accurate and effective operation Before beginning the cleaning process discon...

Page 19: ...ctable baud rate default 9600 8 bits No parity 1 stop bit No handshaking Environmental Operating Temperature 50 F to 104 F 14 C to 40 C Storage Temperature 32 F to 158 F 0 C to 70 C Humidity 85 relative humidity Capacity 550 lb x 0 2 lb 250 kg x 0 1 kg Dimensions Scale Platform 14 7 in W x 14 7 in L x 3 in H 37 5 cm W x 37 5 cm L x 7 6 cm H Overall Height 54 in 137 2 cm Certifications and Approval...

Page 20: ...150 10 5 Digital Physician Scale 16 Visit our website www RiceLake com ...

Page 21: ......

Page 22: ...I 54868 USA U S 800 472 6703 Canada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 Rice Lake Weighing Systems Specifications subject to change without notice www ricelake com PN 126150 Rev G August 18 2022 ...