background image

160-10-7N

Low-Profile Digital Athletic Scale

Software Version 11525

Technical Manual

PN 194095 Rev C

August 18, 2022

Summary of Contents for 160-10-7N

Page 1: ...160 10 7N Low Profile Digital Athletic Scale Software Version 11525 Technical Manual PN 194095 Rev C August 18 2022...

Page 2: ...respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserves the right to...

Page 3: ...ing or obtained by calling 715 234 9171 and asking for the training department Revision History This section tracks and describes the current and previous manual revisions for awareness of major updat...

Page 4: ...Preset Tare 7 3 5 Toggle Tare 7 3 6 Using the Body Mass Index BMI Function 8 3 6 1 LB Mode 8 3 6 2 KG Mode 8 3 7 Troubleshooting 9 4 0 Configuration 10 4 1 Setup Mode 10 4 2 Setup Mode Navigation 10...

Page 5: ...les These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate rad...

Page 6: ...ansport the scale while someone is on the scale Do not allow minors children or inexperienced persons to operate this scale Do not use in the presence of flammable materials Do not use this product if...

Page 7: ...etain the packaging for use in the event that the scale must be returned or moved It must be properly packed with sufficient packing materials Whenever possible use the original shipping carton when s...

Page 8: ...nd remove the tilt stand bracket from the indicator to gain access to the load cell connection Figure 2 2 Remove Tilt Stand 2 Remove the four back retaining screws to remove the back cover to the indi...

Page 9: ...e used for an extended period of time If the LO BAT indicator activates for accurate weighing replace the batteries or connect the scale to an AC power source as soon as possible 2 3 3 Power Connectio...

Page 10: ...ode BMI Does not function when set up as an NTEP certified scale Pressing the BMI key enables access to the BMI Body Mass Index mode defaults when scale is turned on The patient is gets on the scale w...

Page 11: ...tient 1 Press to turn on the scale 0 0 appears on the display along with the ZERO annunciator 2 Place additional item s on the scale 3 Press until the display returns to 0 0 and NET annunciator appear...

Page 12: ...t 7 5 inch is flashing 4 Use and to adjust the height value 5 Press 6 The BMI value and BMI annunciator are shown on the display Press to return to the Weighing mode and the BMI function will be turne...

Page 13: ...E4L BAT Battery low but still usable one bar left on indicator display E4U Battery low and unstable no bars left on indicator display E11 CAL Calibration Error recalibrate scale Err 1 Load cell cable...

Page 14: ...Setup Mode Navigation 1 Ensure the scale is off 2 Remove the back plate by loosening the two Phillips screws and two drilled hex head screws Figure 4 1 3 Press to turn on the indicator START displays...

Page 15: ...ter Configuration Rice Lake Weighing Systems All Rights Reserved 11 4 3 3 Save and Return to Main Menu When a parameters selection value is correct press The next parameter displays When all parameter...

Page 16: ...e set number of minutes 0 always on battery power only does not work if using an external power supply Settings 5 default 6 7 8 9 0 1 2 3 4 LIVE Live Weighing enables or disables live weighing must be...

Page 17: ...essed through the front panel when the scale is in Setup mode Figure 4 3 Top Level Menu 6 Press to advance to the desired menu 7 Press and advance in the manual to the related menu selection for furth...

Page 18: ...0 5 ROUND Scale Resolution sets the scale resolution value Settings 0 2 lb default 0 5 1 0 2 0 5 0 10 0 20 0 0 2 DISP Decimal Point sets the decimal point location Settings 0 0 default 00000 0 0000 0...

Page 19: ...Press DONE displays 9 Press three times to navigate to the top level DONE parameter 10 Press The indicator resumes the self test and returns to weigh mode UNITS Units select the unit of measure Settin...

Page 20: ...nd it s value flashes 5 Press to scroll through the menu items 6 When TEST displays again press two times to navigate to the top level DONE parameter 7 Press The indicator resumes the self test and re...

Page 21: ...weight was either in motion or out of range If displaying weight and not BMI the scale will send out the following 21 character string xxxxxxxxx SP uu SP mmmmm SP CR LF Example 60 1 KG PATIENT SP WEIG...

Page 22: ...Escape Protocol Commands Name ESC Character ESC Value with Parameters Description Reading R R Tells PC the scale is sending a reading immediately following this is the value that is sent Example ESC...

Page 23: ...Zero the scale F Show flash values used for the first flash process L USB On Off not available on USB communication Table 5 5 Maintenance Protocol Commands Escape Protocol Example 1 Escape Protocol E...

Page 24: ...reventing the use of the USB driver Driver protections may need to be temporarily disabled on Windows 10 or later computers to allow for the installation of the USB driver 1 Connect the scale s indica...

Page 25: ...r foil labels are used on both sides of the unit to seal and prevent it from being opened Whomever installs the scale is responsible for placing stickers on the unit The desired sticker location is no...

Page 26: ...ervice personnel Go through the following steps for basic maintenance Check the overall appearance of the entire scale for any obvious signs of damage Inspect the condition of the AC power adapter cor...

Page 27: ...tic power off can be configured Data Communications Connections RS 232 with RJ45 jack USB Baud Rate 9600 Default Bits 8 1 stop bit Parity None Handshaking None Environmental Operating Temperature 41 F...

Page 28: ...160 10 7N Low Profile Digital Athletic Scale 24 Visit our website www ricelake com...

Page 29: ......

Page 30: ...54868 USA U S 800 472 6703 Canada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 Rice Lake Weighing Systems Specifications subject to change without notice www ricelake com PN...