Configuration Settings
15
23
Weight single interval
or multi-interval
0: Single Interval
1: Multi-Interval
Selection of resolution
000: 1/2,500
001: 1/5,000
010: 1/10,000
011: Not Used
100: 1/3,000
101: 1/6,000
110: 1/7,500
111: Not Used
24
Negative weight display
mask
0: Minus gross > 9e
1: Minus gross weight
(DEFAULT)
Recall tare
0: Allow (DEFAULT)
1: Inhibit
Tare range
0: 50% of full scale
(DEFAULT)
1: 100% of full scale
25
Manual tare
cancellation
0: Allow (DEFAULT)
1: Inhibit
Tare subtraction
0: Allow (DEFAULT)
1: Inhibit
Tare accumulation
0: Allow (DEFAULT)
1: Inhibit
Auto tare clear when
re-zero
0: Allow
1: Inhibit (DEFAULT)
26
Digital tare
0: Allow (DEFAULT)
1: Tare
Accumulation when
tare
0: Allow (DEFAULT)
1: Inhibit
Zero tracking when
tare
0: Allow (DEFAULT)
1: Inhibit
Weight reset when tare
0: Allow (DEFAULT)
1: Inhibit
27
Tare auto clear
0: Allow
1: Inhibit (DEFAULT)
Unit weight and
denomination auto
clear
0: .Allow
1: Inhibit (DEFAULT)
Auto clear condition
0: >=Gross 21e & >=Net 5e
(DEFAULT)
1: >=Net 1e & Quantity Not
0
Net/Gross
multi-interval
0: Gross
1: Net (DEFAULT)
28
Accumulation
0: Allow (DEFAULT)
1: Inhibit
Subtraction
0: Allow (DEFAULT)
1: Inhibit
Weight range of data
output
0: Always (DEFAULT)
1: Over 20e
Use * key as manual
key in manual mode
0: Allow (DEFAULT)
1: Inhibit
29
Exit from accumulation
mode after 15 second
time out
0: Allow (DEFAULT)
1: Inhibit
Exit from accumulation
mode when weight
change
0: Allow (DEFAULT)
1: Inhibit
Accumulation without
removing weight
0: Allow
1: Inhibit (DEFAULT)
Accumulation without
change weight (for
>=±10e
0: Allow (DEFAULT)
1: Inhibit
30
Denomination rounding method for 3rd decimal
digit
00: No rounding (DEFAULT)
01: Rounding
10: Truncation
11: Cut up
Amount rounding
method for 3rd decimal
digit
0: Rounding (DEFAULT)
1: Truncation
Plural denomination
accumulation
0: Allow (DEFAULT)
1: Inhibit
31 ~ 47
Not Used (reserved for future use)
SPEC No.
Bit 3
Bit 2
Bit 1
Bit 0
Table 3-2. DMC-782 Weight and Measurement Specifications