Appendix
29
7.2
DMC-782 Error Message List
The DMC-782’s alphanumeric display allows for detailed error messages. Use Table 7-1 below to find the error
message, possible causes for the error and ways to correct the problem. If these suggestions fail to correct the
situation, please contact your RLWS dealer for assistance.
Table 7-1. DMC-782 Error Message List
Error Message
Possible Causes
Corrective Action
O F
When the displayed weight exceeded
c9d, or something is on the platter
when the power is on.
Remove the item on the platter.
U F
When the negative weight exceeds the
display limit.
Rezero the scale or power the on/off button again.
ERROR
When an error occurs in maintenance mode.
Repeat the operation
ERR 01
When the communication between the main
board and the A/D board is not complete.
Contact your RLWS Distributor
ERR 02
When there’s a data flash erase error
Contact your RLWS Distributor
ERR 03
When there’s a data flash program error
Contact your RLWS Distributor
8 8 8 8 8 8
Happens when the scale is not stable when
the power is on.
Place the scale on a firm, flat surface.
tOtAl FULL
When the current total overflows the register
Clear the current total.