Configuration
25
3.2.5
Digital Input Menu
Figure 3-10. Digital Input Menu
TERMIN
CR/LF
CR
Termination character. Selects termination character for data sent from the serial port.
ECHO
OFF
ON
This command enables or disables echoing of the serial commands sent to the indicator.
PRNFRQ
DEMAND
AUTO1
AUTO2
STREAM
Print frequency. Specifies when the indicator sends data to the serial port:
DEMAND:When a PRINT digital input is activated or the KPRINT EDP command received.
AUTO1:Output enabled by scale in motion; transmitted when scale returns to standstill.
AUTO2:Output enabled by scale at center of zero; transmitted when a positive scale weight is at
standstill.
STREAM:Continuous output. See Section 6.3 on page 35 for output format.
Weight data is sent to the serial port in displayed units except when other units are specified
using one of the XGx EDP commands (see Section 5.0 on page 30).
If DEMAND, AUTO1, or AUTO2, is selected for this parameter, serial output is formatted as
follows:
wwwwwww uu GROSS
where
wwwwww
is a 7-digit weight field (leading zeroes suppressed, including decimal point and
minus sign, if required),
uu
is the units designator (lb, kg, oz, or G).
If pounds/ounces (LB/OZ) is specified as the primary units, the serial output is formatted as
shown below:
xxx lb yyyy oz GROSS
where
xxx
is the three-digit pounds weight (including minus sign, if required) followed by
lb
and a space; and
yyyy
is the four-digit ounce weight (including decimal point) followed by
oz
.
DIG IN Menu
Parameter
Choices
Description
Level 2 submenus
DIGIN1
DIGIN2
OFF
ZERO
UNITS
PRINT
Specifies the function activated by digital inputs 1 and 2.
Table 3-6. Digital Input Menu Parameters
SERIAL Menu
Parameter
Choices
Description
Table 3-5. Serial Menu Parameters (Continued)
XXXXXXX
XXXXXXX
VERS
DEFLT
DIG IN
SERIAL
CALIBR
CONFIG
FORMAT
DIGIN1
OFF
DIGIN2
ZERO
UNITS
OFF
ZERO
UNITS
Summary of Contents for IQ plus 2100