Appendix
9-1
In this section:
■
Specifications
■
Assembly Drawings
■
Replacement Parts List
■
ASCII Character Set
■
Software Revision
History
■
Limited Warranty
9.
Appendix
Specifications
Analog Specifications
Measurement Rate
25 updates/second
System Linearity
0.01% of F.S.
Zero Stability
100 nV/
°
C maximum
Span Stability
3 ppm/
°
C maximum
AZM (Zero Track)
Off,
±
0.5, 1, 2 or 3 dd
Zero Band
±
2% or 100% F.S.
Motion Band
Off, 0.5, 1, 2, 3, 5, 10 dd
Calibration Method
Software
Excitation Voltage
10
±
0.5 V DC, maximum 4 - 350
Ω
load cells
Sense Amplifier
Differential amplifier with 6-wire sensing
RFI Protection
Signal, excitation and sense lines protection
3 V/m for 100 kHz to 1 GHz,
≤
1
µ
V suscepti-
bility
Digital Specifications
Digital Filter
Software selectable: 1, 2, 4, 8, 16, 32, 64, 128
Digital Outputs
3 optional 5 VDC TTL-level digital outputs to
indicate Over, Under, and Accept status.
Optional relays available for outputs:
• 3 N/O relays (10 Watts, 0.5 Amp, 100 VDC)
• 3 N/C relays (10 Watts, 0.5 Amp, 100 VDC)
Serial Communication
EDP Port
19200, 9600, 4800, 2400, 1200, 600, 300, and
150 baud. Full duplex RS-232 or simplex 20
mA current loop output; RS-485 optional
Operator Interface
Display
0.8-inch 7-segment, 6-digit high-intensity red
LED display; decimal point available at each
digit
Status Annunciators
lb, kg, g, oz, net, motion, center of zero, neg
Keyboard
8-key touch control with international symbols
Bar Graph
5-segment, 7-range programmable multicol-
ored array tracks Over, Under, Accept status in
relation to target value
Display Resolution
Selectable up to 10,000 dd for NTEP, Class III