The installation in this manual is intended for qualified installers, service technicians or persons
with similar qualified background. Installation and electrical wiring must be done by qualified
professionals and in accordance with all applicable codes and standards, including fire-rated
construction.
•
Range hood may have very sharp edges; please wear protective gloves if it is necessary to remove
any parts for installing, cleaning or servicing.
•
Activating any switch ON before completing installation may cause ignition or an explosion.
•
Due to the size and weight of this range hood, two people installation is recommended.
To reduce the risk of fire, electric shock, or injury to persons:
•
For general ventilating use only. DO NOT use to exhaust hazardous or explosive materials and
vapors.
•
The combustion air flow needed for safe operation of fuel-burning equipment may be affected by
this unit’s operation. Follow the heating equipment manufacturer’s guideline and safety standards
such as those published by the National Fire Protection Association (NFPA), and the American
Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and other local code
authorities.
•
Before servicing or cleaning unit, switch power OFF at service panel and lock service panel to
prevent power from being switched ON accidentally.
•
Clean grease laden surfaces frequently. To optimize performance and to disperse air properly,
make sure to vent air outside. DO NOT vent exhaust into spaces between walls, crawl spaces,
ceiling, attics or garages.
•
Ducted fans MUST always be vented to the outdoors.
•
Use only metal ductwork and this unit MUST be grounded.
•
Sufficient air is needed for proper combustion and exhausting of gases through the duct to prevent
back drafting.
•
When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hid-
den utilities.
•
All electrical wiring must be properly installed, insulated and grounded.
•
Old duct work should be cleaned or replaced if necessary to avoid the possibility of a grease fire.
•
Check all joints on duct work to insure proper connection and all joints should be properly taped.
•
Use this unit only in the manner intended by the manufacturer. If you have questions, contact the
vendor.
Summary of Contents for 45 0 C FM
Page 4: ......
Page 11: ... ...
Page 18: ...18 ...
Page 20: ... bracket bracket UPPER AND LOWER CHIMNEY BRACKETS ...
Page 21: ...Decorative chimney bracket 19 to 38 1 4 ...
Page 26: ......
Page 31: ......
Page 32: ......
Page 33: ... ...
Page 40: ...41 ...
Page 42: ... SUPPORT CHEMINÉE HAUT SUPPORTS CHEMINÉE HAUT ET BAS SUPPORT CHEMINÉE BAS ...
Page 43: ...19 3 4 19 to 38 1 4 ...