LED display
All important actions and operating conditions are indicated by the LED
display and are intended to contribute to finding the causes of failures and
operating errors. The following table lists the meaning of the individual
signals.
Status messages
green
red
green
red
Display
Action
Flashing rapidly
Programming mode
Mastercode 1 & 2
Every 3 seconds
Blocking time (one minute)
is active. Wrong Code
entered four times
1 second
Key entry
1 second
Abort key (“X”) pressed
LEDs flash in turn three
times
Handling error, the rotary
knob was not operated
within the released period
Alternate
Waiting for rotary knob to
be operated
1 second
Lock has been locked /
programming successful
2 seconds
Lock has been unlocked
½ second
Code accepted
3 seconds
Internal malfunction / lock
may have to be replaced
Red LEDs light up first,
then the green LEDs, for
½ a second in each
case
Blocking triggered by
MasterCode 1 cancelled by
means of MasterCode 2
LEDs flash together
three times
Code entry rejected, as
blocking by MasterCode 1
active
LEDs flash together
twice
Warning: battery
replacement is required
shortly
LEDs flash in turn three
times
Battery must be replaced
immediately; lock can no
longer be operated
LEDs flash three times
MasterReset carried out