Manual
63300841
3
0
General information
Capacitive keypad
The SAFE-O-TRONIC
®
63300841
3
0
uses a capacitive keypad.
Notice: The capacitive keypad cannot be operated if you are wearing gloves.
UserCode
The UserCode serves locking or opening of the compartment by the user. Any
four-digit
code can
be programmed as the UserCode.
MasterCode1
MasterCode1 serves the plant operator to open the compartment. It is intended for employees with
restricted locking authorizations. After being opened, the lock is blocked for the entry of a new
UserCode and has to be released with the help of the MasterCode2. A
5 to 10-digit
code can be
programmed as MasterCode1. If the employees are only aware of the MasterCode1, they are
protected against suspicion in cases of hidden thefts. It means if there is a theft and the
compartment has been locked again, the employees cannot come into question as offenders.
Notice: MasterCode1 cannot be programmed with 0 as the first number!
MasterCode2
MasterCode2 can be used by the operator of the facility at any time to
open and close
the
compartment or release the lock. A
5 to 10-digit
code can be programmed as MasterCode2.
Notice: MasterCode2 cannot be programmed with 0 as the first number!
Code overview
The following table contains an overview of the various codes.
4-digit
5 to 10-digit
Open
Close
UserCode
x
-
x
x
MasterCode1
-
x
x
(*)
-
MasterCode2
-
x
x
x
(*) Notice: After using MasterCode1 to open the compartment, the lock must
be released by entering MasterCode2 .
The 6330084130 is delivered in factory mode with test code only. The
programing of master code 1 and 2 is mandatory. It is the responsibility of
the client to program/remember both master codes 1 and 2. If the lock is
locked and both master codes unknown, the lock cannot be reset or open.
In this case, please note that Richelieu will not accept any returns or
claims for this product.
8