GTR057 Installation Manual:
Rev 2
13
Adjust alarm output time
To set the alarm output time (1 ~ 3 minutes)
Factory default is 1 minute)
8 1~3 #
Keypad Tone
The keypad tone can be set to on or off. When on, the device will give the voice when the keys are pressed;
when off, the device will be silent.
Enable the keypad tone
8 6 #
(Factory default setting)
Disable the keypad tone
8 7 #
Change Zone 2 to Doorbell
When there is no need to operate a second door, Zone 2 can be set to operate the doorbell. The wiring is
connecting the doorbell to COM2 and NO2. Press #, the keypad will send the signal to the doorbell.
Zone 2
8 8 # (Factory default)
Doorbell
8 9 #
Remove the alarm
To remove the door forced open warning
Read valid card or Master code #
To remove the door open too long warning
Close the door or Read valid card or Master code #
Anti-Duress
1
When the same card is used in Zone 1 and Zone 2, this card will be an anti-duress card. Please note, you
cannot set an anti-duress PIN.
2
When under forcing, use this card. Both doors are opened. In the meantime, the external alarm alarms.
3
You can set a max of 100 anti-duress cards (The users of Zone 2).