background image

GTR500 & GTR501

SWING GATE OPENER

WITH LIMIT SWITCH AND LED INDICATOR

User Manual

Summary of Contents for GTR500

Page 1: ...GTR500 GTR501 SWING GATE OPENER WITH LIMIT SWITCH AND LED INDICATOR User Manual ...

Page 2: ......

Page 3: ...ls Sold Separately Get Started Step 2 System Learning A Dual Gate B Single Gate Gate moving Logic Checking the Gate Movement LED Indication Function of the LED display Parameter Parameter Learning Parameter Setting Photocell Logic Technical Specification Trouble Shooting Technical Support 16 19 20 21 22 Index General Safety Precaution Installation PART B GTR500 GTR501 GTR502 GTR503 Control System ...

Page 4: ...PART A Gate Motor and Associated Parts ...

Page 5: ...electricity connection phase 5 Installation requires qualified personnel with mechanical and electrical skills 6 Keep the automatic controls remote push button key selectors etc being placed properly and away from children 7 For replace or repair of the motorized system only original parts must be applied Any damage caused by inadequate parts and methods will not be claimed to motor manufacturer 8...

Page 6: ...he moving area 3 No frictions between two gate leafs or with the ground while moving 4 C value is 139mm 5 D can be measured from the gate easily 6 A C D 7 The value of B can be calculated from the value of A and the leaves opening angle Ex If A 160mm with the leaves opening angle of 100 degrees then the value of B is approximate 190mm Please make sure B and A are similar or the same in value that ...

Page 7: ...o 2 1 Avoid tension in the cable during open and close phase 2 Always connect the grounding wire GND Blue Black Green A B Limit Switch no 2 A B no 1 Motor1 Motor1 5V GND Limit1 Limit2 Make sure the gate openers are mounted in horizontal position especially in those positions 1 When gate in CLOSE position 2 When gate in OPEN position 3 When gate at 45o angle position Prior to weld the bracket on th...

Page 8: ...ND Lmt1 Lmt2 Lmt3 Lmt4 Yellow Red Black Green Blue GND Limit 1 3 Limit 2 4 White 5V Yellow Red Black Green Blue GND Limit 1 3 Limit 2 4 White 5V Yellow Red Black Green Blue GND Limit 1 3 Limit 2 4 White 5V Yellow Red Black Green Blue GND Limit 1 3 Limit 2 4 White 5V Wire connection_Open inward Wire connection_Open Outward GND Limit1 Limit2 Motor Motor 5V GND Limit1 Limit2 Motor Motor 5V GND Limit1...

Page 9: ...he above procedures Step1 Push the lid of release chamber and move forward Step2 Insert the key and turn clockwise to the unlock position Step3 then turn clockwise the knob to release the motor Make sure the White bar on the knob is on the position opposite to the triangle indication To restore the automation simply reverse the above procedure Step 1 Step 2 Step 3 5 PART A Gate Motor and Associate...

Page 10: ...ly Gear type Peak Thrust Normal Thrust Operation Stroke Piston extension Opening time Duty Cycle Protection grade IP Protection class Working temperature Operating temperature Absorbed current A Absorbed power W Manual release Enclosure dimensions 4m 350kg 110V 230Vac 50 60Hz 24Vdc Worm gear 3 500N 3 000N 350mm 25 5mm sec 14 sec 20 IP44 20 50 5 5A for maximum 10secs 144W key 917mm 123mm 124mm ...

Page 11: ...se 3 Check the function of photocells or other safety devise Limit switch adjustment Opening position 1 Loosen the screw of limit switch A by hands 2 Slide the switch to the right position 3 Tighten up the screw Closing position 1 Loosen the screw of limit switch B by hands 2 Slide the switch to the right position 3 Tighten up the screw 1 Remove the screw on the anti shaking ring 2 Turn the anti s...

Page 12: ...A1 T4 SW3 UP J1 Q17 R113 R112 R111 R110 R108 R107 R106 R105 R104 R103 R102 SW1 RF LEARN MOV1 K5 J2 F1 DB1 SW4 SET SW5 DOWN NC NO CO PART B GTR500 GTR501 GTR502 GTR503 Control System User Manual Software Version PS21068B CONTROL BOX 8 ...

Page 13: ...e Figure B 4 Secure it on the wall Figure C Control Box Installation Wiring Connection Figure A Figure B Figure C Transformer Antenna Green Box 5V INPUT TX RX LED Display LED2 Push button or Key selector LED4 Photocell 1 LED3 Photocell 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 UP SET DOWN RF LEARN LED2 LED4 LED3 11 Lit Lit Lat Lat M1 M1 M2 M2 5V S1 S2 GND Lmt1 Lmt2 GND...

Page 14: ...Key GND GND GND GND Lmt1 GND PC190 PCB1 40121 377 A1 T4 SW3 UP Q17 R113 R112 R111 R110 R108 R107 R106 R105 R104 R103 R102 J5 SW1 RF LEARN RF1 MOV1 K5 K3 K2 K1 J4 J3 J7 J2 F1 DB1 J8 SW4 SET SW5 DOWN NC NO CO NC NO CO CO NO NC CO NO NC NC NO CO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 LED2 LED3 LED4 Red 5V Black GND Green Limit1 Blue Limit2 Motor1 Power Limit Switch LED P...

Page 15: ...attery The remaining positive and negative terminals go to the control board as per the photo above 1 2 3 4 5 6 7 8 Lit Lit Lat Lat M1 M1 M2 M2 5V S1 S2 GND Lmt1 Lmt2 GND Lmt3 Wi fi Device Sold Separately LED description Blue LED will be flashing during WIFI pairing and be ON when completed Green LED will be flashing if WB 001 receives signal from APP If your home WIFI disconnects the green light ...

Page 16: ...ut Voltage Contact Current Response Time Emitting Element Operation Indicator Dimensions Output Method Current Consumption Connection Method Housing Material Water Proof Safety Standard Through Beam MAX 15m AC DC 12 24V TX 30mA Max RX 25 mA Max 100mS Infrared LED Wave Length 940nm RX Red LED On beam broken Off beam aligned TX Red LED On 63 63 30 mm Relay Output Beam aligned RX 25ma TX 30ma Beam br...

Page 17: ...ds without any new remote learn then the LED will be off The transmitter learning is completed figure 1 figure 1 RF Learn New Remote Press any desired button UP A B SET DOWN RF LEARN 3 Sec RF LEARN SET B Remote Learning without Control Board 1 Press the A B buttons on the OLD remote and hold down for at least 5s then release them the alarm will buzz 2 secs and LED will display CS 2 Press any desir...

Page 18: ...meter setting of F1 Dual Single before going into system learning Restore system default setting and P Press ress and Hold the UP DOWN button for 5 secs and panel restores back to default setting Note 1 1 LE LED LE LED 2 2 A 1 Dual Gate Slave Gate Close 2 Master Gate Close 3 Master Gate Open 4 Slave Gate Open 5 Slave Gate Close 6 Master Gate Close B Single Gate 1 Master Gate Close 2 Master Gate Op...

Page 19: ...2 19 19 19 19 19 19 19 19 LED2 LED4 LED3 Function Of The LED Display LED Display Programmable Functions LED Display Programmable Functions When the gate is opening the LED Display show OPN for 2s and then change to Amp current indication When the gate is stopped the LED Display show STP until next commend has been made after 10s no further movement the LED turns to OFF When the gate is closing the...

Page 20: ...escription Dual Single Gate Overcurrent for Gate Opening Overcurrent for Gate Closing Motor Speed for Opening F1 F3 F4 F5 F11 F22 F23 F31 F32 F33 F34 F41 F42 F43 F44 F51 F52 F F5 54 4 Over current Default Limit Switch Hall Sensor 2A 3A 4A Default 5A 2A 3A 4A Default 5A 50 of full speed 60 of full speed 70 of full speed 80 of full speed 1 The factory setting is F12 1 The factory setting is F33 1 Th...

Page 21: ... 40 of full speed Default 50 of full speed 1 The factory setting is F83 Deceleration Point for Opening F91 F92 F93 F94 F9 F95 75 of full distance 80 of full distance 85 of full distance Default 90 of full distance 95 of full distance 1 The factory setting is F93 Deceleration Point for Closing FA1 FA2 FA3 FA4 FA FA5 75 of full distance 80 of full distance 85 of full distance Default 90 of full dist...

Page 22: ...h for 3 seconds before the gate operates If set OFF the flash light will operate with motor at the same time 2 The factory setting is FG0 1 The factory setting is FH0 1 The factory setting is FI0 1 The factory setting is FJ0 1 If the function is FK2 the motor will be reversed for 0 25 sec to release the tension 2 The factory setting is FK1 1 The factory setting is FL1 The UP and Down buttons will ...

Page 23: ...n to NO met Table FW Over current Sensitivity Setting F Para W1 FW2 FW3 FW4 1 The factory setting Description is FW5 FW5 FW6 FW9 F FW7 W7 FW8 FWA er 0 1 sec 0 3 sec 0 2 sec 0 4 sec 0 6 sec 0 5 sec Default 0 8 sec 0 7 sec 0 9 sec 1 sec Type of Safety Device FULLY CLOSED FULLY OPENED STOP DURING MOVING CLOSING OPENING PH1 Photocell CLOSE No effect Reload automatic closing time Reload automatic closi...

Page 24: ...vice FULLY CLOSED FULLY OPENED STOP DURING MOVING CLOSING PH1 Photocell OPEN CLOSE No effect No effect PH2 Photocell OPEN CLOSE No effect Position of Gate When safety devices are activated Open Open Reload automatic closing time Reload automatic closing time No effect No effect Technical Specification Main power supply Back up battery Receiver board Installation Operating Temperature Dimension 230...

Page 25: ... the LED3 and LED4 on the board are off which is located on the button right of the board if it is on check the photocell connection and function Check that the battery is 24V Make sure your connections aren t loose The power input is feeding in 24V The gate is free from any obstructions The arm is locked into place A good way to test this is if you can move the gate freely then it won t work via ...

Page 26: ...ines all responsibility for any consequences resulting from improper use of the product or use which is different from the expected and specified in the present documentation Richmond Wheel Castor Co declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing closing structures door gates etc as well as from any deformation which mig...

Page 27: ......

Page 28: ......

Reviews: