PART B: Control System User Manual
18
Definition
Safety Device Function Mode
Pedestrian Mode
Flashing Light
Photocell
1
Activation
Photocell 2 Activation
Alarm Buzzer
Electric Latch Mode
LED Direction
Over Current Reverses Time
when Close
F
E
F
F
F
G
F
H
F
I
F
J
F
K
F
L
F
N
F
E
1
F
E
2
F
E
3
F
E
4
F
F
0
F
F
1
F
G
0
F
G1
F
H
0
F
H
1
F
I
0
F
I
1
F
J
0
F
J
1
F
K1
F
K2
F
L
0
F
L
1
F
N
0
F
N
1
F
N
2
F
N
3
F
N
4
F
N
5
F
N
6
Mode 1
(Default)
Mode 2
Mode 3
Mode 4
Function OFF
Function ON
(Default)
Function OFF
(Default)
Function ON
Function OFF
(Default)
Function ON
Function OFF
(Default)
Function ON
Function OFF
(Default)
Function ON
Standard Gate Opening
(Default)
Release Gate Tension before
Opening (Gate Reversing for 0.25s)
When Terminal Block is at
bottom
(
for swing gate motor
)
When Terminal Block is at
top
(for articulated-arm motor
>> Default
)
Function OFF
(Default)
0.1 sec
0.2 sec
0.3 sec
0.4 sec
0.5 sec
0.6 sec
1.
Please see
P.19
photocell adjustment for photocell
logic
2.
The factory setting is "
FE
1".
1.
The factory setting is "F
F
1".
2.
When it's set "FF0":
there won't be any response while pressing
remotes & D/Skey
terminals
3.
When it's set "FF1":
*single gate installation >> master gate
fully opens
*
dual gate installation >> master gate opens 50%
1.
When function F
G
1, the light will flash for 3 seconds
before the gate operates. If set OFF, the flash light will
operate with motor at the same time.
2.
The factory setting is "F
G
0".
1. The factory setting is "F
H
0".
1. The factory setting is "F
I
0".
1. The factory setting is "F
J
0".
1.
If the function is F
K2
, the motor will be reversed for
0.25 sec. to release the tension.
2.
The factory setting is "F
K1
".
1. The factory setting is "F
L
1
".
The UP(
▲
) and Down(
▼
) buttons will switch according to
the parameter setting.
When F
L
0, button SW
5
stands for
▲
(UP) , and button
SW
3
stands for
▼
(DOWN).
When F
L1
, button SW
3
stands for
▲
(UP) , and button
SW
5
stands for
▼
(DOWN)
1. The factory setting is "F
N
0"
LED Display
Parameter
Table
Description
LED Display
Definition
Parameter
Table
Description
F
O
A
Button
Function
(Remote)
F
O
0
F
O
1
F
O
2
F
O
3
F
O
4
Function OFF
Open-Stop-Close-Stop (Default)
Pedestrian Mode
Turn auto-closing OFF via remote
Open ONLY
1. The factory setting is "F
O1
"
F
P
B
Button
Function
(Remote)
F
P
0
F
P
1
F
P
2
F
P
3
F
P
4
Function OFF
Open-Stop-Close-Stop
Pedestrian Mode (Default)
Turn auto-closing OFF via remote
Open ONLY
1. The factory setting is "F
P2
"
F
R
C
Button
Function
(Remote)
F
R
0
F
R
1
F
R
2
F
R
3
F
R
4
Function OFF (Default)
Open-Stop-Close-Stop
Pedestrian Mode
Turn auto-closing OFF via remote
Open ONLY
1. The factory setting is "F
R0
"
F
S
D
Button
Function
(Remote)
F
S
0
F
S
1
F
S
2
F
S
3
F
S
4
Function OFF (Default)
Open-Stop-Close-Stop
Pedestrian Mode
Turn auto-closing OFF via remote
Open ONLY
1. The factory setting is "F
S