FUSING UNIT
20 June 2005
3-68
4. Separate the fan connectors [A] (
x 1).
NOTE:
When re-connecting, thread the connector correctly between the gaps.
5. Close the right door.
6. Use a short screwdriver to remove the fan plate [B] (
x 2).
7. Pull the fan [C] out of the machine.
B195R973.WMF
B195R919.WMF
[A]
[B]
[C]