SERVICE PROGRAM MODE TABLES
20 June 2005
5-18
No. addtnl. sheets for 2nd HR stripper cleaning
3905 3*
This SP prescribes the number of pages to print continuously before the fusing
motor is switched on/off twice.
[6 ~ 49 /
30
/ 1]
Unless you change this setting, 15 sec. after the end of every print job of 30 to 49
continuous pages, the
1st Cleaning
will be done twice (fusing motor is switched
on/off twice at 15 sec. intervals).
No. addtnl. sheets for 3rd HR stripper cleaning
3905 4*
This SP prescribes the number of pages to print continuously before the 1st
Cleaning is done once at the end of the print job, pauses 45 sec., and then
executes again.
[50 ~ 999/
100
/ 1]
Unless you change this setting, 15 sec. after the end of every print job of 50 to 999
continuous pages, the fusing motor will switch on for 15 sec., switch off for 4 sec.
switch on for 15 sec. and then switch off. Switching the fusing motor on again for
15 sec. after 45 sec. have elapsed after the 1st Cleaning is called the
2nd
Cleaning
.
No. of times for 3rd HR stripper cleaning
3905 5*
This SP prescribes the number of times that the cleaning pattern of SP3905 004 is
repeated for the number of pages prescribed by SP3905 004.
[0~5/
0
/1]
Unless you change this setting, the cleaning pattern of SP3904 (1st Cleaning,
then the 2nd Cleaning after 35 sec.) is not repeated. If you change this setting to
"1" for example, then the pattern will be repeated once.
Job/HR stripper cleaning priority setting
3905 6*
This SP setting determines whether cleaning is canceled if another job starts while
cleaning is in progress.
0
: New job priority
1: Cleaning priority
Setting this SP to "1" ensures that every cleaning cycle executes completely
before another job is allowed to start.