Tables
5816
Remote Service
I/F Setting
5816 1
Turns the remote diagnostics off and on.
[0~2/1]
0: Remote diagnostics off.
1: Serial (CSS or NRS) remote diagnostics on.
2: Network remote diagnostics.
CE Call
5816 2
Lets the customer engineer start or end the remote machine check with CSS or
NRS; to do this, push the center report key
Function Flag
5816 3
Enables and disables remote diagnosis over the NRS network.
[0~1/1]
0: Disables remote diagnosis over the network.
1: Enables remote diagnosis over the network.
Device Information Call Display
5816 6
Controls if the item for initial setting of the screen for the NRS device-information
notification-call is shown.
[0~1/1]
0: Enabled. Item initial setting not shown.
1: Disable. Item for initial setting shown.
SSL Disable
5816 7
Controls if RCG (Remote Communication Gate) confirmation is done by SSL during
an RCG send for the NRS over a network interface.
[0~1/1]
0: Yes. SSL not used.
1: No. SSL used.
RCG Connect Timeout
5816 8
Sets the length of time (seconds) for the time-out when the RCG (Remote
Communication Gate) connects during a call via the NRS network.
[1~90/1 sec.]
RCG Write to Timeout
5816 9
Sets the length of time (seconds) for the time-out when sent data is written to the
RCG during a call over the NRS network.
[0~100/1 sec.]
RCG Read Timeout
5816 10
Sets the length of time (seconds) for the timeout when sent data is written from the
RCG during a call over the NRS network.
[0~100/1 sec.]
Port 80 Enable
5816 11
Controls if permission is given to get access to the SOAP method over Port 80 on
the NRS network.
[0~1/1]
0: No. Access denied
1: Yes. Access granted.
Connection Method
5816 16
Selects how the remote service is connected.
0
: Internet
1: Dial-up