T
echnical
B
ulletin
PAGE: 12/12
Updated: 30
th
December 2007:
Changes in bold italics
Model:
Jupiter-C1
Date:
15-Sep-04
No.:
RB149000h
11. Others
Subject Symptom
RTB
#
Cause Solution Note
Meter charge
counter
An external meter charge
device counter mistakenly
increments twice
001
006
Engine
firmware
Install the latest engine
firmware (ver 1.09b or
later).
If not available, change
SP5-121 to "1: Paper
Exit".
Need Ver.
1.09B
Hard disk
initialization
and data loss
Hard disk initialization and
data loss after switching
the machine on
005
003a
System
firmware
(occurs with
version 1.12.2
or older)
Install the latest system
firmware (ver 1.14.1 or
later)
External
counter
counts up
incorrectly
B/W pages in the data sent
from the driver as a Color
job are not counted up by
the external counting
device when the device is
set to prohibit B/W prints.
Note: The mainframe
counters increment
correctly.
021 Printer
firmware
Install the latest printer
firmware (ver. 1.03.1 or
later)
Remote
service
system
Concorde captures the
Development Counter data
instead of the Page
Counter.
003c System
firmware
Install new system
firmware (ver. 1.20 or
later).
Total counter The value for the single
color counter is not
included in the value for
the printer total counter
003f System
firmware
Install new system
firmware (ver. 1.23 or
later).
Noise Booklet
finisher
040
Grounding
plate damaged
during
installation
Be careful during
installation.
Repair or replace the
grounding plate.
The machine
stalls
After multiple PCL forms
are sent to it
021b Printer
firmware
Install the latest printer
firmware (ver. 1.06 or
later)
Damaged
platen cover
A small area on the lower
front edge of the platen
cover sheet is damaged.
044
The sheet is
gradually worn
down because
the user always
touches it when
opening/closing
the cover.
Temporary: Cover the
damaged part with tape, or
turn the sheet around.
Permanent: Install the
modified platen cover
sheet
Modified
sheet: P/N
G3291371
Cannot go
to the Ready
state
MB
B149
017
Incorrect type
of hard disk
installed.
Install the correct type of
hard disk.