SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC816-36
to94
D
Subsystem error
Energy save I/O subsystem detected some abnormality.
• Energy save I/O subsystem defective
• Energy save I/O subsystem detected a controller board error (non-
response).
• Error was detected during preparation for transition to STR.
• Turn the main power off/on.
• Replace the controller board.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC818-00
D
Watchdog timer error
• The system program fell into a bus-hold state or an endless loop of
the program interruption occurred, causing other process to stop.
• System program defective
• Controller board defective
• Optional board defective
• Turn the main power off/on.
• Replace the controller board.
• Replace the optional devices.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC833-00
D
Self-diagnostic error: Engine I/F ASIC
Self-diagnostic error: Video I/F
6. Troubleshooting
140
Summary of Contents for Aficio MP 171
Page 1: ...Model Gim P1a Machine Code M171 Field Service Manual September 2014 ...
Page 2: ......
Page 14: ...12 ...
Page 34: ...3 Preventive Maintenance 32 ...
Page 48: ...3 OPU Board x 7 4 Replacement and Adjustment 46 ...
Page 59: ...2 Hold the grip to pull the toner cartridge A out Toner Cartridge 57 ...
Page 105: ...2 Rear Cover Switch A x 1 Hook Electrical Components 103 ...
Page 106: ...4 Replacement and Adjustment 104 ...
Page 120: ...5 System Maintenance 118 ...
Page 166: ...MEMO 164 EN ...
Page 167: ...Model Gim P1a Machine Code M171 Appendices September 2014 ...
Page 168: ......
Page 186: ...2 Appendices Preventive Maintenance Tables 18 ...
Page 259: ...MEMO 91 ...
Page 260: ...MEMO 92 EN ...