SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC995-**
D
CPM setting error
Comparison of machine serial number (11 digits) and machine
identification code.
Details:
• Machine serial number cannot be identified because of BCU
replacement or malfunctioning.
• Machine serial number cannot be identified because of NV-RAM
replacement
Machine serial number (11 digits) or machine identification code does
not match.
• Replace the board(s) to match the CPM of the controller and BCU
boards.
• Turn the main power switch off and on.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC997-00
B
Application function selection error
• The application has not responded to the set command created by
SCS within a certain period of time.
• The application selected ended abnormally.
Software bug
• Check whether an option required by the application (RAM, DIMM,
board) is installed properly.
• Check whether downloaded applications are correctly configured.
(Take necessary countermeasures specific to the application in which
the error occurs. In some applications, the logs can be taken from
the monitor. If this option is available, analyze the logs.)
6. Troubleshooting
144
Summary of Contents for Aficio MP 171
Page 1: ...Model Gim P1a Machine Code M171 Field Service Manual September 2014 ...
Page 2: ......
Page 14: ...12 ...
Page 34: ...3 Preventive Maintenance 32 ...
Page 48: ...3 OPU Board x 7 4 Replacement and Adjustment 46 ...
Page 59: ...2 Hold the grip to pull the toner cartridge A out Toner Cartridge 57 ...
Page 105: ...2 Rear Cover Switch A x 1 Hook Electrical Components 103 ...
Page 106: ...4 Replacement and Adjustment 104 ...
Page 120: ...5 System Maintenance 118 ...
Page 166: ...MEMO 164 EN ...
Page 167: ...Model Gim P1a Machine Code M171 Appendices September 2014 ...
Page 168: ......
Page 186: ...2 Appendices Preventive Maintenance Tables 18 ...
Page 259: ...MEMO 91 ...
Page 260: ...MEMO 92 EN ...