SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC998-00
D
Application start error
• After power on, no application program is registered to the system
within a predetermined period of time. (No application starts or ends
normally.)
• Even if they are started, all applications have become unable to be
rendered due to an unknown defect.
• Software bug
• An option required by the application (RAM, DIMM, board) is not
installed properly
• Turn the main power switch off and on.
• Check whether an option required by the application (RAM, DIMM,
board) is installed properly.
• Check whether downloaded applications are correctly configured.
• Replace the Controller Board.
Service Call
145
Summary of Contents for Aficio MP 171
Page 1: ...Model Gim P1a Machine Code M171 Field Service Manual September 2014 ...
Page 2: ......
Page 14: ...12 ...
Page 34: ...3 Preventive Maintenance 32 ...
Page 48: ...3 OPU Board x 7 4 Replacement and Adjustment 46 ...
Page 59: ...2 Hold the grip to pull the toner cartridge A out Toner Cartridge 57 ...
Page 105: ...2 Rear Cover Switch A x 1 Hook Electrical Components 103 ...
Page 106: ...4 Replacement and Adjustment 104 ...
Page 120: ...5 System Maintenance 118 ...
Page 166: ...MEMO 164 EN ...
Page 167: ...Model Gim P1a Machine Code M171 Appendices September 2014 ...
Page 168: ......
Page 186: ...2 Appendices Preventive Maintenance Tables 18 ...
Page 259: ...MEMO 91 ...
Page 260: ...MEMO 92 EN ...