Main SP Tables-2
SP2-XXX (Drum)
2001
[C biasControl]
2-001-001
C setting
E
[-1350 to -900 / -1020 / 1V/step]
C: bias value.
• This setting is available when the bias
control is Off.
2-001-002
C(low) setting
E
[-400 to -200 / -350 / 50V/step]
C(low): The value of C(low) output.
2-001-011
Vd_ref_lowhumi
E
[-700 to -400 / -420 / 10V/step]
Displays or adjusts the target dark potential
(Vd) in the Env Division, low humidity.
• This setting is available when the bias
control is On.
2-001-012
Vd_ref_midhumi
E
[-700 to -400 / -470 / 10V/step]
Displays or adjusts the target dark potential
(Vd) in the Env Division, mid humidity.
• This setting is available when the bias
control is On.
2-001-013
Vd_ref_highhumi
E
[-700 to -400 / -490 / 10V/step]
Displays and adjusts the target dark potential
(Vd) in the Env Division, high humidity.
• This setting is available when the bias
control is On.
Main SP Tables-2
27
Summary of Contents for Aficio MP 171
Page 1: ...Model Gim P1a Machine Code M171 Field Service Manual September 2014 ...
Page 2: ......
Page 14: ...12 ...
Page 34: ...3 Preventive Maintenance 32 ...
Page 48: ...3 OPU Board x 7 4 Replacement and Adjustment 46 ...
Page 59: ...2 Hold the grip to pull the toner cartridge A out Toner Cartridge 57 ...
Page 105: ...2 Rear Cover Switch A x 1 Hook Electrical Components 103 ...
Page 106: ...4 Replacement and Adjustment 104 ...
Page 120: ...5 System Maintenance 118 ...
Page 166: ...MEMO 164 EN ...
Page 167: ...Model Gim P1a Machine Code M171 Appendices September 2014 ...
Page 168: ......
Page 186: ...2 Appendices Preventive Maintenance Tables 18 ...
Page 259: ...MEMO 91 ...
Page 260: ...MEMO 92 EN ...