5507
[Supply Alarm]
Enables or disables the notifying a supply call via the @Remote.
5-507-003 Toner
C
[0 or 1 / 1 / 1/step]
Switches the control call on/off for the stapler
installed in the finisher. DFU
If you select "1" the alarm will sound when the
copier detects toner end.
0: Off
1: On
5-507-006 WasteTonerBottle
C
[0 or 1 / 1 / 1/step]
0: Off
1: On
5-507-080 Toner Call Timing
C
[0 or 1 / 0 / 1/step]
0: At replacement
1: AtLessThanThresh
Changes the timing of the "Toner Supply Call"
via the @Remote, when the following
conditions occur.
5-507-081 Toner Call Thresh
C
[10 or 90 / 10 / 10%/step]
5515
[SC/Alarm Setting]
With NRS (New Remote Service) in use, these SP codes can be set to issue an SC
call when an SC error occurs. If this SP is switched off, the SC call is not issued when
an SC error occurs.
5-515-001 SC Call
C
[0 or 1 / 1 / 1/step]
0: Off
1: On
5-515-004 User Call
C
5-515-006 Communication Test Call
C
5-515-007 Machine Information Notice
C
5-515-010
Supply Automatic Ordering
Call
C
5801
[Memory Clear]
Main SP Tables-5
43
Summary of Contents for Aficio MP 171
Page 1: ...Model Gim P1a Machine Code M171 Field Service Manual September 2014 ...
Page 2: ......
Page 14: ...12 ...
Page 34: ...3 Preventive Maintenance 32 ...
Page 48: ...3 OPU Board x 7 4 Replacement and Adjustment 46 ...
Page 59: ...2 Hold the grip to pull the toner cartridge A out Toner Cartridge 57 ...
Page 105: ...2 Rear Cover Switch A x 1 Hook Electrical Components 103 ...
Page 106: ...4 Replacement and Adjustment 104 ...
Page 120: ...5 System Maintenance 118 ...
Page 166: ...MEMO 164 EN ...
Page 167: ...Model Gim P1a Machine Code M171 Appendices September 2014 ...
Page 168: ......
Page 186: ...2 Appendices Preventive Maintenance Tables 18 ...
Page 259: ...MEMO 91 ...
Page 260: ...MEMO 92 EN ...