5-816-052 Test Flag
C
[0 to 255 / 0 / 1/step]
Displays whether or not to execute a test call
when executing change of time-specified
setting value by G/W.
Displays the specified date when executing
the center polling to which the test call is
executed.
0: Does not execute a test call
1: Execute a test call
5-816-053 Update Result
C
[0 to 255 / 0 / 1/step]
5-816-060 Mgn Expir Time
C
[2592000 to 15552000 / 2592000 /
1sec/step]
A reference value (second) for determining
that the certification is expiring during RC
Gate operation.
During RC Gate operation, when it reaches
the date when the period set by this SP
before expiration date written on the
certificate is left, it detects that validity is close
to expiration and notifies that to Gateway.
If notification failed, it notifies again at the
date when the 1/4 and 1/10 of the set
period is left.
5-816-061 NotiTime ExpTime
C
[ - / 0 / - ]
Proximity of the expiration of the certification.
5-816-062 HTTP Proxy use
C
[ - / - / - ]
Determines if the proxy server is used when
the machine communicates with the service
center.
Main SP Tables-5
49
Summary of Contents for Aficio MP 171
Page 1: ...Model Gim P1a Machine Code M171 Field Service Manual September 2014 ...
Page 2: ......
Page 14: ...12 ...
Page 34: ...3 Preventive Maintenance 32 ...
Page 48: ...3 OPU Board x 7 4 Replacement and Adjustment 46 ...
Page 59: ...2 Hold the grip to pull the toner cartridge A out Toner Cartridge 57 ...
Page 105: ...2 Rear Cover Switch A x 1 Hook Electrical Components 103 ...
Page 106: ...4 Replacement and Adjustment 104 ...
Page 120: ...5 System Maintenance 118 ...
Page 166: ...MEMO 164 EN ...
Page 167: ...Model Gim P1a Machine Code M171 Appendices September 2014 ...
Page 168: ......
Page 186: ...2 Appendices Preventive Maintenance Tables 18 ...
Page 259: ...MEMO 91 ...
Page 260: ...MEMO 92 EN ...