5-816-207 Instl:Rgstltn Rst
C
[0 to 255 / 0 / 1/step]
Displays a number that indicates the
registration result.
0: Succeeded
2: Registration in progress
3: Proxy error (proxy enabled)
4: Proxy error (proxy disabled)
5: Proxy error (Illegal user name or
password)
8: Other error
9: Registration executing
20: Dial-up authentication error
21: Answer tone detection error
22: Carrier detection error
23: Invalid setting value (modem)
24: Low power supply current
25: Unplugged modem
26: Busy line
5-816-208
Instl:ErrorCode
C
[-2147483647 to 2147483647 /
- / -]
Cause
Code
Meaning
Illegal Modem Parameter
-11001
Chat parameter error
-11002
Chat execution error
-11003
Unexpected error
-11004
Cutting process occurred during
modem communication.
-11005
NCS reboot occurred during modem
communication.
Main SP Tables-5