SC900 (Others)
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC900-00
D
Electronic counter error
The value provided by the electronic total counter is outside the normal
range.
• Unexpected NVRAM installed
• Defective NVRAM
• NVRAM data corruption
• Data is stored in an unexpected area due to external causes.
• The count requests made by SRM upon receiving the PRT have not
yet been processed.
Install an NVRAM device designed specifically for the model.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC920-**
B
Printer application error
A serious application error that stops the machine from operating is
detected.
• 920-00
At PM startup, no response was returned within the specified period
of time.
• 920-01
A time-out occurred during PM operation.
• 920-02
WORK memory acquisition failed.
• 920-03
The filter process cannot be started.
• 920-04
The filter process was aborted.
Turn the main power switch off and on.
6. Troubleshooting
142
Summary of Contents for Aficio MP 171
Page 1: ...Model Gim P1a Machine Code M171 Field Service Manual September 2014 ...
Page 2: ......
Page 14: ...12 ...
Page 34: ...3 Preventive Maintenance 32 ...
Page 48: ...3 OPU Board x 7 4 Replacement and Adjustment 46 ...
Page 59: ...2 Hold the grip to pull the toner cartridge A out Toner Cartridge 57 ...
Page 105: ...2 Rear Cover Switch A x 1 Hook Electrical Components 103 ...
Page 106: ...4 Replacement and Adjustment 104 ...
Page 120: ...5 System Maintenance 118 ...
Page 166: ...MEMO 164 EN ...
Page 167: ...Model Gim P1a Machine Code M171 Appendices September 2014 ...
Page 168: ......
Page 186: ...2 Appendices Preventive Maintenance Tables 18 ...
Page 259: ...MEMO 91 ...
Page 260: ...MEMO 92 EN ...