SERVICE CALL CONDITIONS
28 August, 2000
2-4
2.1.1 PERIODIC SERVICE CALL
The periodic service call notifies the service station of the machine’s condition. The
call is made at a time interval programmed in the following RAM addresses:
Parameters
Address (H)
Call interval: 01 through 15 month(s) (BCD)
00: Periodic Service Call Disabled
480379
Date and time of the next call
Year: last two digits of the year (BCD)
48037A
Month: 01 through 12 (BCD)
48037B
Day: 01 through 31 (BCD)
48037C
Hour: 00 through 23 (BCD)
48037D
To change these settings after programming, change the call interval. The machine
then automatically changes the remaining parameters by referring to the interval
and the current date and time.
2.1.2 PM CALL
If PM alarm is enabled by the base copier’s SP mode and PM call is enabled by
system switch 01, the machine will make an automatic service call when the base
copier’s PM counter reaches the PM interval.
2.1.3 EFFECTIVE TERM OF SERVICE CALLS
If a time limit for the effectiveness of service calls is programmed, the machine
stops making automatic service calls after the time limit.
Program the time limit at the following addresses. This function is disabled when all
of these addresses are 00(H).
Address (H)
Year: last two digits of the year (BCD)
480383
Month: 01 through 12 (BCD)
480384
Day: 01 through 31 (BCD)
480385