102
Detailed Descriptions
The OCFS actuator [1] on the top of the actuator arm is not symmetrical.
The side of the actuator away from the tank has an extended wing [2] (shaded
blue in the drawing) attached to it.
Because this actuator is wider than a normal actuator, it takes longer for it to move
from right to left through and then out of the gap of the OCFS.
The sides of the sub tanks are flexible.
The sides may bend out slightly when the tank is full [1], and then gradually
collapse as ink is drained from the tank [2] and [3].
The actual level of the ink does not change at [2] and [3] even though there is less
ink in the tank.
However, if air enters the tank [4], the air sensors at the top of the tank will be
exposed and detect air in the tank.
Summary of Contents for D124
Page 1: ...D124 DETAILED DESCRIPTIONS MANUAL ...
Page 2: ......
Page 20: ...D124 14 Detailed Descriptions 1 2 GENERAL LAYOUT ...
Page 24: ...D124 18 Detailed Descriptions 1 4 MOTORS CLUTCHES AIR RELEASE SOLENOID ...
Page 28: ...D124 22 Detailed Descriptions 1 6 ORIGINAL PATH PAPER PATH SENSORS ...
Page 62: ...D124 56 Detailed Descriptions 3 1 2 SCAN JOB IMAGE DATA FLOW 3 1 3 PRINT JOB IMAGE DATA FLOW ...