T
echnical
B
ulletin
PAGE: 1/7
Reissued:5-Dec-13
Model:
Large Capacity Tray RT5060 (D516)
Date:
6-Nov-13
No.:
RD516005
RTB Reissue
The items in
bold italics
were corrected or added.
Symptom
Jam 80 or paper skew with paper longer than 423.8mm (SRA3, DLT, etc.)
Cause
The drive and idle rollers on the LCT exit guide plate do not completely separate to release
the paper for the side-to-side registration adjustment.
The above symptoms could occur with LCTs manufactured after March 2013, because
these are side effects of the modification to the LCT exit guide plate in March 2013.
Before the modification in Mar 2013
After the modification in Mar 2013
The gap between the drive and idle rollers is insufficient and paper could get caught.
S/N of affected units
See the last pages of this bulletin.
Subject:
Procedure for preventing JAM80 and Skews on LCT
Prepared by:
Shinnosuke Sasaki
From:
1st PP Tech Service Sec., PP Tech Service Dept.,
Classification:
Troubleshooting
Mechanical
Paper path
Product Safety
Part information
Electrical
Transmit/receive
Other ( )
Action required
Service manual revision
Retrofit information
Tier 2
Exit Guide Plate was originally arched in the direction indicated with the arrow.
Exit Guide Plate was arched in the opposite direction for higher feed ability,
but caused side effects.