T
echnical
B
ulletin
PAGE: 2/7
Reissued:5-Dec-13
Model:
Large Capacity Tray RT5060 (D516)
Date:
6-Nov-13
No.:
RD516005
Solution
The exit guide plate will be re-modified in Nov 2013.
Request
Check the serial number to see if the LCT is affected or not on your next visit. If affected,
perform the rework described below. RCL will supply the following parts/tools required for
the rework free of charge.
D0749911:
BEARING:KIT
IMPORTANT: Information exclusive for Ricoh Europe
In addition to the s/n, check if a green dot (as shown in the photo below) is attached to the
left side of the s/n label. If attached, the machine has already been reworked at RPL and
therefore rework is unneeded even if the machine has an affected s/n.
Rework procedure for the affected units
1. Disconnect the LCT from the mainframe. Turn the LCT 90 degrees as shown and
connect the I/F cable to the mainframe.
2. Turn on the main power.