![background image](http://html1.mh-extra.com/html/ricoh/fax3700l/fax3700l_service-manual_1456522172.webp)
8000A8(H) - User parameter switch 08 *
Bit 0 and 1: Multi-copy reception (optional memory card required)
Bit 1 0 Setting
X 0 Disabled
0 1 Faxes from senders whose RTIs/CSIs are specified for this feature are
multicopied.
1 1 Faxes from senders whose RTIs/CSIs are not specified for this feature
are multicopied.
Bits 2 and 3: Authorized reception
Bit 3 2 Setting
X 0 Disabled
0 1 Faxes from senders whose RTIs/CSIs are specified for this feature are
accepted.
1 1 Faxes from senders whose RTIs/CSIs are not specified for this feature
are accepted.
Bits 4 and 5: Specified cassette selection (optional PFU required)
Bit 3 2 Setting
X 0 Disabled
0 1 Faxes from senders whose RTIs/CSIs are specified for this feature are
printed to the paper in a specified cassette.
1 1 Faxes from senders whose RTIs/CSIs are not specified for this feature
are printed to the paper in a specified cassette.
Bits 6 and 7: Forwarding (optional memory card required)
Bit 1 0 Setting
X 0 Disabled
0 1 Faxes from senders whose RTIs/CSIs are specified for this feature are
forwarded.
1 1 Faxes from senders whose RTIs/CSIs are not specified for this feature
are forwarded.
8000A9(H) - User parameter switch 09
Bits 0 and 1: Memory lock (optional memory card required)
Bit 1 0 Setting
X 0 Disabled
0 1 Faxes from senders whose RTIs/CSIs are specified are kept in the
memory until a memory lock ID is entered.
1 1 Faxes from senders whose RTIs/CSIs are not specified are kept in the
memory until a memory lock ID is entered.
Bits 2 to 7: Not used
8000AA(H) - User parameter switch 10 *
Bit 0: Reverse order printing
0: Disabled, 1: Enabled
Bit 1: Into 1 (printing two half-letter (A5) messages onto one Letter (A4) paper)
0: Disabled, 1: Enabled
Bits 2 to 6: Not used
Bit 7: Halftone type
0: Error diffusion, 1: Dither
8000AB(H) - User parameter switch 11
Bits 0 to 5: Not used
Bit 6: Printout of messages received while acting as a forwarding station 0: Off, 1: On
Bit 7: Polling Standby duration
0: Once, 1: No limit
August 2nd, 1995
SERVICE TABLES AND PROCEDURES
SERVICE RAM ADDRESSES
4-75