4
4-20
Performing Setup from the Control Panel
Subnet Mask
This option lets you modify the subnet mask for printing with TCP/IP over Ethernet.
To set the subnet mask, enter one of the following values:
•
255.0.0.0
if the IP address starts with a number less than 128
•
255.255.0.0
if the IP address starts with a number from 128 through 191
•
255.255.255.0
if the IP address starts with a number greater than 191
N
OTE
:
Confirm the subnet mask setting with your network administrator before
proceeding. In some cases, the required setting may be different from that listed.
Gateway Address
[127.0.0.1]
This option appears only if you answered No to Get Gateway Address Automatically,
or if you selected RARP as the protocol.
Use this option to set the gateway address for printing with TCP/IP. If your network
uses a gateway, you must change the default to a correct gateway address for your
network.
TCP/IP Setup with Token Ring
Enable TCP/IP for Token Ring, and enter the IP address and subnet mask. If your
TCP/IP network has a gateway and users outside the gateway plan to print to the
E-820 using TCP/IP, enter the gateway address.
Network Setup
Protocol Setup
TCP/IP Setup
Token Ring Setup
Enable TCP/IP for Token Ring
Yes/No [Yes]
Select Yes if you have a TCP/IP network connected to the E-820 over Token Ring.
If you use Token Ring, you must enable TCP/IP for Token Ring in order to enable
WebTools.
N
OTE
:
If you are using TCP/IP for printing from Windows computers, enabling
TCP/IP here also lets you use the Fiery utilities from Windows computers using
TCP/IP protocols.