- Action -
Is the charge corona wire cleaner knob fully inserted?
Is the cleaner mechanism working properly?
Yes
No
Fully insert the knob or fix the cleaner pad bracket.
Are the charge and transfer corona units correctly installed?
Yes
No
Install the charge and transfer corona units correctly.
Are the charge and transfer corona wires broken?
No
Yes
Replace the corona wires.
Is leakage occurring in the endblocks or receptacles?
No
Yes
Replace the defective parts.
Are the imaging unit drive gears worn or broken?
No
Yes
Replace the drive gears.
Check CN102-4 and 102-5 (Charge/Transfer trigger lines)
1) If the signal stays HIGH after the
key is pressed, replace the
main board.
2) If the charge or transfer corona does not turn on even if the signal
changes to LOW, replace the high voltage supply board.
If there is no problem with the signal lines, replace the drum if the sensitivity
does not recover even when the drum is not exposed to light.
COPY QUALITY
20 December 1996
7-2
Summary of Contents for FT 4015
Page 2: ...SECTION 1 OVERALL MACHINE INFORMATION...
Page 14: ...SECTION 2 DETAILED DESCRIPTIONS...
Page 71: ...SECTION 3 INSTALLATION...
Page 90: ...SECTION 4 SERVICE TABLES...
Page 118: ...SECTION 5 PREVENTIVE MAINTENANCE...
Page 126: ...SECTION 6 REPLACEMENT AND ADJUSTMENT...
Page 190: ...SECTION 7 TROUBLESHOOTING...
Page 222: ...SECTION 8 OPTIONS...
Page 223: ...SECTION 9 APPENDIX TIMING CHART...
Page 225: ...COPIER A219 ELECTRICAL COMPONENT LAYOUT 4 2 3 1 5 6 A219S500 wmf...
Page 226: ...10 15 14 13 12 11 9 8 7 18 17 16 A219S501 wmf...
Page 227: ...24 40 23 28 27 26 25 19 20 21 22 29 39 31 32 33 34 35 36 38 37 30 A219S502 wmf...