2) Image Density Adjustment Factor (SP34)
Depending on the SP34 setting, the development bias and the exposure
lamp settings are increased or decreased during ADS mode.
SP34 Setting
Setting
Dev. Bias
Exposure Lamp
0
Normal
0
0
1
Light
–40 V
0
2
Dark
+40 V
0
3
Lightest
–40 V
+4 steps
4
Darkest
+40 V
–4 steps
1 step = 0.5 V (120 V machines) or 1.0 V (230 V machines)
3) Manual Image Density Setting Factor
Depending on the manual image density setting on the operation panel, the
exposure lamp voltage is changed as shown in the table below:
Manual ID
Level
1
2
3
4
5
6
7
Exposure
Lamp Voltage
Factor
V
0
– 6
steps
V
0
– 4
steps
V
0
– 2
steps
V
0
V
0
+ 2
steps
V
0
+ 6
steps
V
0
+ 12
steps
Development
Bias Voltage
(Volts)
–200
–200 –200
–200 –200
–240
–240
V
0
: Base lamp voltage setting (SP48)
1 step = 0.5 V (120 V machines) or 1.0 V (230 V machines)
Lighter
Darker
OPTICS
20 December 1996
2-12
Summary of Contents for FT 4015
Page 2: ...SECTION 1 OVERALL MACHINE INFORMATION...
Page 14: ...SECTION 2 DETAILED DESCRIPTIONS...
Page 71: ...SECTION 3 INSTALLATION...
Page 90: ...SECTION 4 SERVICE TABLES...
Page 118: ...SECTION 5 PREVENTIVE MAINTENANCE...
Page 126: ...SECTION 6 REPLACEMENT AND ADJUSTMENT...
Page 190: ...SECTION 7 TROUBLESHOOTING...
Page 222: ...SECTION 8 OPTIONS...
Page 223: ...SECTION 9 APPENDIX TIMING CHART...
Page 225: ...COPIER A219 ELECTRICAL COMPONENT LAYOUT 4 2 3 1 5 6 A219S500 wmf...
Page 226: ...10 15 14 13 12 11 9 8 7 18 17 16 A219S501 wmf...
Page 227: ...24 40 23 28 27 26 25 19 20 21 22 29 39 31 32 33 34 35 36 38 37 30 A219S502 wmf...