1. INSTALLATION REQUIREMENTS
1.1 ENVIRONMENT
1. Temperature Range:
10°C to 30°C (50°F to 87°F)
2. Humidity Range:
15% to 90% RH
3. Ambient Illumination:
Less than 1,500 lux (Do not exposure to direct
sunlight.)
4. Ventilation:
Room air should turn over at least 3 times per
hour
5. Ambient Dust:
Less than 0.15 mg/m
3
(4 x 10
-3
oz/yd
3
)
6. If the place of installation is air-conditioned or heated, do not place the
machine:
1) Where it will not be subjected to sudden temperature changes.
2) Where it will not be directly exposed to cool air from an air-conditioner.
3) Where it will not be directly exposed to heat from a heater.
7. Do not place the machine where it will be exposed to corrosive gasses.
8. Do not install the machine at any location over 2,000 m (6,500 feet)
above sea level.
9. Place the copier on a strong and level base.
10. Do not place the machine where it may be subjected to strong vibrations.
1.2 MACHINE LEVEL
1. Front to back:
Within 5 mm (0.2") of level
2. Right to left:
Within 5 mm (0.2") of level
Installat
ion
20 December 1996
INSTALLATION REQUIREMENTS
3-1
Summary of Contents for FT 4015
Page 2: ...SECTION 1 OVERALL MACHINE INFORMATION...
Page 14: ...SECTION 2 DETAILED DESCRIPTIONS...
Page 71: ...SECTION 3 INSTALLATION...
Page 90: ...SECTION 4 SERVICE TABLES...
Page 118: ...SECTION 5 PREVENTIVE MAINTENANCE...
Page 126: ...SECTION 6 REPLACEMENT AND ADJUSTMENT...
Page 190: ...SECTION 7 TROUBLESHOOTING...
Page 222: ...SECTION 8 OPTIONS...
Page 223: ...SECTION 9 APPENDIX TIMING CHART...
Page 225: ...COPIER A219 ELECTRICAL COMPONENT LAYOUT 4 2 3 1 5 6 A219S500 wmf...
Page 226: ...10 15 14 13 12 11 9 8 7 18 17 16 A219S501 wmf...
Page 227: ...24 40 23 28 27 26 25 19 20 21 22 29 39 31 32 33 34 35 36 38 37 30 A219S502 wmf...