CHANGING THE IMAGING UNIT
When "iu" and the copy set number appear on the copy counter by
turns, it is time to change the imaging unit and the ozone filter (copying
is still possible). When "iu" is continuously displayed, copies cannot be
made until the imaging unit and the ozone filter are replaced.
Note:
When you set the new imaging unit and the ozone filter, be
careful not to touch the blue material (OPC).
Note:
Do not expose the imaging unit (especially the blue mate-
rial) to the light.
How To Change The Imaging Unit
1
Open the top unit.
❐
To stop the top unit from springing
up, keep one hand on it while
opening it.
2
Remove the used imaging unit
with the used toner bottle being
careful not to spill the toner.
❐
Make sure to remove the imaging
unit to prevent spilling toner while
moving the copier.
❐
Do not shake the imaging unit to
the right or left.
3
Open the new imaging unit
cardboard box. Grasp the edge
of the imaging unit and pull it
straight out to remove the unit.
Then take out the unit from the
styrene foam.
➊
➋
➋