7.4 ORIGINAL SIZE DETECTION
The DF determines original size (both width and length) through the use of
the original width sensor [A], registration sensor, and pulse generator sensor
[B]. The original’s length is calculated by counting the number of pulses from
the pulse generator while the registration sensor is on.
Original size detection is necessary for the feed-in/feed-out timing of the DF.